AutoView® Switch For Technical Support: Installer/User Guide www.avocent.com/support For models: 1415, 1515 and 2015 Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA Tel: +1 256 430 4000 Fax: +1 256 430 4031 Avocent International Ltd.
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AutoView® Switch 1415/1515/2015 Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AutoView, OutLook and OSCAR are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners. © 2007 Avocent Corporation. All rights reserved.
Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Dangerous Voltage This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Power On This symbol indicates the principal on/off switch is in the on position.
v TABL E OF CONTEN TS Table of Contents List of Figures ................................................................................................................ vii List of Tables ................................................................................................................... ix Chapter 1: Product Overview.......................................................................................... 1 Features and Benefits .............................................................
vi AutoView 1415/1515/2015 Switch Installer/User Guide Changing Your Switch Mode ........................................................................................................... 41 Chapter 4: Advanced Operations ................................................................................. 43 Using Administrator Privileges ....................................................................................................... 43 Appendices......................................................
vii L IS T O F F IG URE S List of Figures Figure 1.1: Example of an AutoView Switch Configuration ............................................................. 4 Figure 2.1: AutoView Switch Horizontal Installation ...................................................................... 8 Figure 2.2: Basic AutoView Switch Configuration .......................................................................... 9 Figure 2.3: AutoView 2015 Switch Configuration with a Cascaded Switch ............................
viii AutoView 1415/1515/2015 Switch Installer/User Guide Figure 4.2: User Setup Menu (Administrator Only)........................................................................ 44 Figure 4.3: User Edit Menu (Administrator Only).......................................................................... 45 Figure 4.4: User Access Menu (Administrator Only)...................................................................... 45 Figure A.1: AVRIQ Status Dialog Box .............................................
ix L I S T OF T A B L ES List of Tables Table 2.1: Legacy Switch Support ................................................................................................... 12 Table 3.1: OSCAR Interface Status Symbols ................................................................................... 18 Table 3.2: OSCAR Interface Navigation Basics ............................................................................. 19 Table 3.3: Setup Features to Manage Routine Tasks for Your Servers.............
x AutoView 1415/1515/2015 Switch Installer/User Guide
1 CHA PTER 1 Product Overview Features and Benefits The AutoView® 1415/1515/2015 switches integrate Avocent field-proven analog keyboard, video and mouse (KVM) switching technology with advanced cable management, flexible access for two simultaneous users, USB support and a patented, easy-to-use interface. This AutoView series of KVM switches conveniently supports all major server platforms and features powerful on-screen management for easy system configuration and server selection.
2 AutoView 1415/1515/2015 Switch Installer/User Guide Two-User Share Mode The AutoView 1415/1515/2015 switches feature a Share Mode function that allows two users to gain access to a primary server. The user configurable time-out feature allows you to determine the amount of time (up to 600 seconds) for the target to remain idle before the other user can take control of the target.
Chapter 1: Product Overview 3 Cascading expansion Each AutoView switch supports up to 16 directly attached servers and can conveniently scale to support more. You can expand your system using cascadable Avocent products such as other AutoView or OutLook® switches. This extra “cascade” of units allows you to attach up to 256 servers in one system. See Chapter 2 for more information.
4 AutoView 1415/1515/2015 Switch Installer/User Guide AutoView Switch (Cascaded) Legacy Switch (Cascaded) Rack of Servers AVRIQ or IAC Module Critical Server Analog Connection AutoView Switch (Main) Analog Connection Figure 1.1: Example of an AutoView Switch Configuration Safety Precautions To avoid potential video and/or keyboard problems when using Avocent products: • Ιf the building has 3-phase AC power, ensure that the computers and monitors are on the same phase.
Chapter 1: Product Overview • 5 Use only with grounded outlets at both the computer and monitor. When using a backup Uninterruptible Power Supply (UPS), power the computer, the monitor and the AutoView switch off the supply. NOTE: The AC inlet is the main disconnect. Rack mount safety considerations • Elevated Ambient Temperature: If installed in a closed rack assembly, the operation temperature of the rack environment may be greater than room ambient.
6 AutoView 1415/1515/2015 Switch Installer/User Guide
7 CHA PTER 2 Installation Getting Started Before installing your AutoView switch, refer to the following list to ensure you have all items that shipped with the AutoView switch, as well as other items necessary for proper installation.
8 AutoView 1415/1515/2015 Switch Installer/User Guide Figure 2.1: AutoView Switch Horizontal Installation CAUTION: Rack Loading - Overloading or uneven loading of racks may result in shelf or rack failure, causing damage to equipment and possible personal injury. Do not exceed your rack load rating. To install the 1U switch mounting bracket: 1. Remove the first two screws on each side of the switch. 2. Line up the holes in the “long side” of the kit’s side brackets with the screw holes in the switch.
Chapter 2: Installation CAUTION: To reduce the risk of electric shock or damage to your equipment - Do not disable the power cord grounding plug. The grounding plug is an important safety feature. - Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times. - Disconnect the power from the unit by unplugging the power cord from either the electrical outlet or the unit.
10 AutoView 1415/1515/2015 Switch Installer/User Guide To connect a server using an AVRIQ module: 1. Locate the AVRIQ modules for your AutoView switch. 2. Attach the appropriately color-coded cable ends to the keyboard, monitor and mouse ports on the first server you will be connecting to the appliance. 3. Attach one end of a CAT 5 cable to the RJ-45 connector on the AVRIQ module. 4. Connect the other end of the CAT 5 cable to the desired ARI port on the back of your AutoView switch. 5.
Chapter 2: Installation 11 In this configuration, the local port OSCAR interface is disabled in switches cascaded below the main AutoView switch. To cascade multiple AutoView switches: 1. Connect the cascaded AutoView switch to each server as described in the previous Installing the AutoView Switch section. 2. Connect the local peripherals to analog user A and/or B of the main switch as described in To connect local peripherals. 3.
12 AutoView 1415/1515/2015 Switch Installer/User Guide Analog User A Analog User B AutoView 2015 Switch ARI Ports 15 Primary Servers AutoView 2015 Switch (cascaded) ACI Port 16 Secondary Servers Figure 2.3: AutoView 2015 Switch Configuration with a Cascaded Switch Adding Legacy Switches You can add legacy switches to the AutoView switching system for easy integration into your existing configuration. In a cascaded system, each ARI port will accommodate up to 24 servers.
Chapter 2: Installation Local Analog User A AutoView 2015 Switch AVRIQ Module PS/2, USB, Sun and serial cables are available OutLook ES Switch Server 1 AVRIQ Module AutoView 200/400 Switch Server 2 Figure 2.
14 AutoView 1415/1515/2015 Switch Installer/User Guide Local Analog User A Local Analog User B AutoView 1415/1515/2015 Switch Secondary Servers AVRIQ Module PS/2, USB, Sun and serial modules are available AutoView 1415/1515/2015 Switch Secondary Servers Figure 2.5: AutoView Switch Configuration with AutoView 1415/1515/2015 Switches NOTE: The PS2IAC modules can be utilized in Figure 2.5.
Chapter 2: Installation 15 To add a legacy KVM switch: 1. Mount the primary KVM switch into your rack cabinet. 2. Connect one end of a CAT 5 cable to an available port on the back of your AutoView switch. 3. Attach the keyboard, monitor and mouse connectors of the AVRIQ module to a user port on your cascaded switch. 4. Attach the other end of the CAT 5 cabling to the RJ-45 connector on the AVRIQ module. 5.
16 AutoView 1415/1515/2015 Switch Installer/User Guide
17 CHA PTER 3 Basic Operations Controlling Your System at the Analog Ports The AutoView switch features one or two analog port sets on the back of the switch that allow you to connect a monitor and a PS/2 or USB keyboard and mouse for direct analog access. The AutoView switch uses the OSCAR interface, featuring intuitive menus to configure your system and select servers.
18 AutoView 1415/1515/2015 Switch Installer/User Guide NOTE: You can also press the Control key twice, the Alt key twice or the Shift key twice within one second to launch the OSCAR interface. See Changing the display behavior later in this chapter for further details. You can use this key sequence in any place you see Print Screen throughout this installer/user guide. Viewing the status of your switch The status of the servers in your system is indicated in the right columns of the Main dialog box.
Chapter 3: Basic Operations 19 To select the previous server: Press Print Screen and then Backspace. This key combination toggles you between the previous and current connections. To disconnect the user from a server: Press Print Screen and then Alt+0. This leaves the user in a free state, with no server selected. The status flag on your desktop displays Free. Soft switching Soft switching is the ability to switch servers using a hotkey sequence.
20 AutoView 1415/1515/2015 Switch Installer/User Guide Table 3.2: OSCAR Interface Navigation Basics (Continued) This Keystroke Does This F1 Opens the Help screen for the current dialog box. Escape Closes the current dialog box without saving changes and returns to the previous one. In the Main dialog box, it closes the OSCAR interface and returns to the flag. In a message box, it closes the pop-up box and returns to the current dialog box.
Chapter 3: Basic Operations 21 Configuring OSCAR Interface Menus You can configure your AutoView switch from the Setup menu within the OSCAR interface. Select the Names button when initially setting up your switch to identify servers by unique names. Select the other setup features to manage routine tasks for your servers from the OSCAR interface menu. Table 3.
22 AutoView 1415/1515/2015 Switch Installer/User Guide Figure 3.2: Setup Dialog Box (User) Figure 3.3: Setup Dialog Box (Admin) NOTE: Figure 3.3 displays for the Administrator if Local User Accounts are enabled, or for all user if Local User Accounts are disabled. Assigning server names Use the Names dialog box to identify individual servers by name rather than by port number. The Names list is always sorted by port order.
Chapter 3: Basic Operations 23 Figure 3.4: Names Dialog Box NOTE: If the server list changes, the mouse cursor will turn into an hourglass as the list is automatically updated. No mouse or keyboard input will be accepted until the list update is complete. To assign names to servers: 1. In the Names dialog box, select a server name or port number and click Modify. The Name Modify dialog box displays. Figure 3.5: Name Modify Dialog Box 2. Type a name in the New Name box.
24 AutoView 1415/1515/2015 Switch Installer/User Guide NOTE: If an AVRIQ module has not been assigned a name, the EID is used as the default name. Assigning device types The AutoView switch automatically discovers cascaded KVM switches, but you will need to specify the number of ports on the cascaded switch through the Devices dialog box. You will see an Sw-8 or Sw-24 display in the Type category for the cascaded switch.
Chapter 3: Basic Operations 25 Figure 3.7: Device Modify Dialog Box 3. Choose the number of ports supported by your cascaded switch and click OK. If the number of desired ports is not listed, click Other and type in port number between 4 and 24 ports. 4. Repeat steps 1 to 3 for each port requiring a device type to be assigned. 5. Click OK in the Devices dialog box to save settings. NOTE: Changes made in the Device Modify dialog box are not saved until you click OK in the Devices dialog box.
26 AutoView 1415/1515/2015 Switch Installer/User Guide To choose the default display order of servers: 1. Select Name to display servers alphabetically by name. -orSelect EID to display servers numerically by EID number. -orSelect Port to display servers numerically by port number. 2. Click OK. To set up key sequences to launch the OSCAR interface: 1. Click the box next to the key sequence you want to start the OSCAR interface. Unchecking all boxes will leave Print Screen as the default. 2.
Chapter 3: Basic Operations 27 Figure 3.9: Keyboard Box To change the keyboard country code: 1. Press Print Screen to launch the OSCAR interface. The Main dialog box will appear. 2. Click Setup-Keyboard. The Keyboard dialog box displays. 3. Select your desired keyboard country code and click OK. 4. A Keyboard Warning dialog box will appear to confirm your changes. 5. Click OK for changes to take effect. Figure 3.
28 AutoView 1415/1515/2015 Switch Installer/User Guide 3. Select your desired language. 4. Click OK for changes to take effect. Figure 3.11: Language Dialog Box Controlling the status flag The status flag displays on your desktop and shows the name or EID number of the selected server or the status of the selected port. Use the Flag dialog box to configure the flag to display by server name or EID number, or to change the flag color, opacity, display time and location on the desktop. Table 3.
Chapter 3: Basic Operations 29 Figure 3.12: Flag Dialog Box To determine how the status flag is displayed: 1. Select Name or EID to determine what information will be displayed. 2. Select Displayed to show the flag all the time or select Timed to display the flag for only five seconds after switching. 3. Select a flag color in Display Color. 4. In Display Mode, select Opaque for a solid color flag or select Transparent to see the desktop through the flag. 5.
30 AutoView 1415/1515/2015 Switch Installer/User Guide Once engaged, your console will remain locked until you press any key or move the mouse. You will then need to type in your password to continue. Use the Security dialog box to lock your console with password protection, set or change your password and enable the screen saver. NOTE: If a password has been previously set, you will have to enter the password before you can access the Security dialog box.
Chapter 3: Basic Operations 31 3. Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation of password protection and the screen saver feature. 4. For Mode, select Energy if your monitor is ENERGY STAR® compliant; otherwise select Screen. CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with ENERGY STAR. 5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you to the Security dialog box. 6.
32 AutoView 1415/1515/2015 Switch Installer/User Guide 4. Choose Energy if your monitor is ENERGY STAR compliant; otherwise select Screen. CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with ENERGY STAR. 5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you to the Security dialog box. 6. Click OK. NOTE: Activation of the screen saver mode disconnects the user from a server; no server is selected.
Chapter 3: Basic Operations 33 To turn off the screen saver: 1. In the Security dialog box, clear Enable Screen Saver. 2. Click OK. To immediately turn on the screen saver: Press Print Screen, then press Pause. Displaying Version Information The OSCAR interface enables you to display the versions of the AutoView switch, as well as the AVRIQ module and IAC module firmware. For optimum performance, keep your firmware current. For more information, see Appendix A. To display version information: 1.
34 AutoView 1415/1515/2015 Switch Installer/User Guide Figure 3.16: Target Selection Dialog Box (Admin) 4. Select an AVRIQ or IAC module to view and click the Version button. The Target Version dialog box displays. For more information on loading firmware, see Appendix A. Figure 3.17: Target Version Dialog Box 5. Click the Load Firmware button to view the load firmware screen. The Load Firmware button will not appear in the user version of the Target Selection Dialog Box.
Chapter 3: Basic Operations 35 Figure 3.18: Firmware Warning Dialog Box To decommission an AVRIQ module: Decommissioning an AVRIQ module restores the factory defaults in Sun, USB and PS/2 AVRIQ modules only. 1. Press Print Screen. The Main dialog box will appear. 2. Click Commands - Display Versions. The Version dialog box displays. 3. Click the Target button to view individual AVRIQ module version information. The Target Selection dialog box displays. 4. Click the Decommission button. 5.
36 AutoView 1415/1515/2015 Switch Installer/User Guide To add servers to the scan list: 1. If the OSCAR interface is not open, press Print Screen. The Main dialog box will appear. 2. Click Setup - Scan. The Scan dialog box displays. Figure 3.19: Scan Dialog Box 3. The dialog box contains a listing of all servers attached to your appliance. Click the checkbox next to the servers you wish to scan. -orDouble-click on a server’s name or port. -orPress Alt and the number of the server you wish to scan.
Chapter 3: Basic Operations 37 Figure 3.20: Commands Dialog Box NOTE: Figure 3.17 shows the Commands screen for the administrator and local user when the Enable User Accounts feature is turned off. The restricted user will only have access to the Display Versions, Device Reset and Log Out buttons. 3. Select Scan Enable in the Commands dialog box. 4. Click X to close the Commands dialog box. NOTE: Scanning will begin when the Main dialog box or flag is displayed.
38 AutoView 1415/1515/2015 Switch Installer/User Guide NOTE: AVRIQ or IAC modules may appear to be offline while being upgraded. Figure 3.21: Diagnostics Dialog Box Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to the left of each item as that test finishes. The following table details each of the tests. Table 3.
Chapter 3: Basic Operations 39 Figure 3.22: Diagnostics Warning Dialog Box 3. Click OK to begin diagnostics. -orClick X or press Escape to exit the dialog box without running a diagnostic test. 4. All users are disconnected and the Diagnostics dialog box displays. 5. As each test is finished, a pass (green circle) or fail (red x) symbol displays. The test is complete when the last test’s symbol displays.
40 AutoView 1415/1515/2015 Switch Installer/User Guide Figure 3.23: Broadcast Dialog Box NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all servers receiving a broadcast to interpret keystrokes identically. Specifically, the Caps Lock and Num Lock modes must be the same on all keyboards. While the appliance attempts to send keystrokes to the selected servers simultaneously, some servers may inhibit and thereby delay the transmission.
Chapter 3: Basic Operations 41 Figure 3.24: Broadcast Enable Confirm/Deny Dialog Box 5. Click OK to enable the broadcast. Click X or press Escape to cancel and return to the Commands dialog box. 6. If broadcasting is enabled, type the information and/or perform the mouse movements you want to broadcast from the switch. Only servers in the list are accessible. NOTE: The other user is disabled when Broadcast Mode is enabled.
42 AutoView 1415/1515/2015 Switch Installer/User Guide Figure 3.25: Switch Dialog Box 3. Select either Preemptive or Cooperative as your Switch Mode. 4. Click OK to save changes. Click X or press Escape to cancel. Setting the Share Mode feature The Share Mode feature of the AutoView 1415/1515/2015 switches allows two users to gain access to a primary server. To enable Share Mode: 1. Press Print Screen. The Main dialog box will display. 2. Click Setup - Switch. The Switch dialog box displays. 3.
43 CHA PTER 4 Advanced Operations Using Administrator Privileges The AutoView 1415/1515/2015 switches allow up to four users and one administrator to log into a switch, with the administrator having the ability to restrict users from accessing the targets via the Security menu. The administrator can edit, access and/or delete user accounts. Figure 4.1: Security Menu To access the User Setup screen (administrator only): 1. Click the Enable User Account checkbox in the Security menu.
44 AutoView 1415/1515/2015 Switch Installer/User Guide Figure 4.2: User Setup Menu (Administrator Only) User Setup menu functions (administrator only) The User Setup menu allows the administrator to edit, access and/or delete a user account. The menu is only accessible if the Enable User Account checkbox is enabled in the Security menu. The AutoView 1415/1515/2015 switches will have four standard user accounts, with the default names of User1, User2, User3 and User4. To edit a user: 1.
Chapter 4: Advanced Operations 45 Figure 4.3: User Edit Menu (Administrator Only) The Username field displays default names that can be edited by the administrator. Usernames must be between 1 to 15 characters. Administrators can also set user passwords in the User Edit menu. Passwords must be between 5 to 12 characters and must contain at least one number and one alpha character. Administrators must verify new passwords by retyping the password in the Repeat Password field.
46 AutoView 1415/1515/2015 Switch Installer/User Guide The Clear All button allows the administrator to clear access to all ports for a given user instead of deleting the account. The Check All button allows the administrator to assign all available KVM ports to any user. NOTE: Changes are not saved to memory until the administrator clicks OK on the User Setup screen. User Setup menu - Delete (administrator only) The Delete button in the User Access menu allows an administrator to delete user accounts.
47 A P P EN D IC ES Appendices Appendix A: Flash Upgrades Upgrading the AutoView switch You can upgrade the firmware of your AutoView switch by using a special update utility provided by Avocent. This utility automatically configures the port communications settings to allow direct downloading from the connected server.
48 AutoView 1415/1515/2015 Switch Installer/User Guide • In the selected COM port Advanced Port settings, verify that the FIFO buffers are selected and that the receive buffer is set to High. CAUTION: While upgrading, do not use your server for anything else or switch between windows. Close all other windows if necessary. If the upgrade was unsuccessful (such as during a power outage), repeat the procedure.
Appendices Figure A.
50 AutoView 1415/1515/2015 Switch Installer/User Guide Appendix B: Technical Specifications Table B.
Appendices Table B.1: Product Specifications (Continued) AutoView Switch Product Specifications AC-input voltage rating 100 to 240 VAC Autosensing AC-input current rating 0.
52 AutoView 1415/1515/2015 Switch Installer/User Guide Appendix C: Sun Advanced Key Emulation Certain keys on a standard Type 5 (US) Sun keyboard can be emulated by key press sequences on a PS/2 keyboard. To enable Sun Advanced Key Emulation mode and use these keys, press and hold Ctrl+Shift+Alt and then press the Scroll Lock key. The Scroll Lock LED blinks. Use the indicated keys in Table C.1 as you would use the advanced keys on a Sun keyboard. Table C.
Appendices 53 For example: For Stop + A, press and hold Ctrl+Shift+Alt and press Scroll Lock, then F1 + A. These key combinations will work with the AVRIQ-USB module (if your Sun system comes with a USB port) as well as the Sun AVRIQ-VSN and AVRIQ-WSN modules. With the exception of F12, these key combinations are not recognized by Microsoft Windows. Using F12 performs a Windows key press.
54 AutoView 1415/1515/2015 Switch Installer/User Guide Appendix D: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service. To resolve an issue: 1. Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined. 2. Check our web site at www.avocent.
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Commutateur AutoView® 1415/1515/2015 Guide d’installation et d’utilisation Avocent, le logo Avocent, The Power of Being There, AutoView, OutLook et OSCAR sont des marques déposées d’Avocent Corporation ou de ses filiales. Toutes les autres marques sont la propriété exclusive de leurs détenteurs respectifs. © 2007 Avocent Corporation. Tous droits réservés.
Instructions Ce symbole est destiné à attirer votre attention sur la présence de consignes importantes liées au fonctionnement et à la maintenance (entretien) dans la documentation accompagnant le matériel. Tension dangereuse Ce symbole est destiné à vous avertir de la présence de « tensions dangereuses » non isolées à l’intérieur de l’appareil pouvant être suffisamment élevées pour constituer un risque de choc électrique pour les individus.
iii T A B L E D ES MAT I È R ES Liste des Figures.............................................................................................................. v Liste des Tableaux ......................................................................................................... vii Chapitre 1: Présentation du produit............................................................................... 1 Caractéristiques et avantages.........................................................................
iv Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Chapitre 4: Opérations avancées ................................................................................. 43 Utilisation des privilèges d’administrateur .....................................................................................43 Annexes .......................................................................................................................... 47 Annexe A : Mises à jour Flash................
v LISTE DES FIGURES Figure 1.1 : Exemple de configuration du commutateur AutoView ..................................................4 Figure 2.1 : Installation horizontale du commutateur AutoView ......................................................8 Figure 2.2 : Configuration de base du commutateur AutoView........................................................9 Figure 2.3 : Configuration du commutateur AutoView 2015 avec un commutateur en cascade........................................................
vi Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 3.25 : Boîte de dialogue Commutateur ................................................................................42 Figure 4.1 : Menu Sécurité ..............................................................................................................43 Figure 4.2 : Menu Utilisateur (administrateur uniquement)...........................................................44 Figure 4.3 : Menu Modifier utilis.
vii L ISTE DES TABLEAUX Tableau 2.1 : Compatibilité avec les commutateurs classiques ......................................................12 Tableau 3.1 : Symboles d’état utilisés dans l’interface OSCAR......................................................18 Tableau 3.2 : Concepts de base de la navigation dans OSCAR ......................................................19 Tableau 3.3 : Fonctions de configuration pour gérer les tâches de routine des serveurs ..............21 Tableau 3.
viii Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015
1 CHAPITRE 1 Présentation du produit Caractéristiques et avantages Les commutateurs AutoView® 1415/1515/2015 intègrent la technologie Avocent de commutation analogique KVM (clavier, vidéo, souris) avec une fonctionnalité de gestion de câble avancée, un accès flexible pour une utilisation simultanée par deux utilisateurs, une prise en charge USB et une interface utilisateur brevetée et facile à utiliser.
2 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Mode de partage pour deux utilisateurs Les commutateurs AutoView 1415/1515/2015 comportent une fonction Mode de partage permettant à deux utilisateurs d’accéder à un serveur principal simultanément. La fonction Délai d’expiration configurable par l’utilisateur permet de définir une période d’inactivité pour un équipement cible donné (de 1 à 600 secondes) avant qu’un autre utilisateur puisse en prendre le contrôle.
Chapitre 1 : Présentation du produit 3 Montage en cascade Chaque commutateur AutoView permet de relier directement jusqu’à 16 serveurs et peut facilement être modifié pour en accommoder un plus grand nombre. Vous pouvez ainsi étendre votre système en utilisant des produits Avocent montables en cascade, tels que les commutateurs AutoView ou OutLook®. Il vous est alors possible de connecter jusqu’à 256 serveurs sur un seul système. Pour de plus amples informations, reportez-vous au chapitre 2.
4 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Commutateur AutoView (monté en cascade) Commutateur classique (monté en cascade) Rack de serveurs Module AVRIQ ou IAC Serveur critique Connexion analogique Commutateur AutoView (principal) Connexion analogique Figure 1.
Chapitre 1 : Présentation du produit • Vérifiez la polarité et la mise à la terre des prises de courant alternatif de l’ordinateur et du moniteur. • Utilisez uniquement des prises de courant reliées à la terre, pour l’ordinateur et le moniteur. Lors de l’utilisation d’une alimentation de secours, mettez sur le même réseau l’ordinateur, le moniteur et le commutateur AutoView. 5 NOTA : La meilleure façon de mettre l’équipement hors tension est de le débrancher de la prise de courant.
6 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015
7 CHAPITRE Installation 2 Démarrage Avant d’installer le commutateur AutoView, consultez la liste ci-dessous pour vous assurer que vous disposez de tous les éléments livrés avec le matériel ainsi que des autres éléments nécessaires à l’installation.
8 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 2.1 : Installation horizontale du commutateur AutoView ATTENTION : Chargement du rack : une mauvaise répartition de la charge ou une surcharge risque d’affaiblir le rack et de faire plier les étagères, entraînant d’éventuels dommages matériels et corporels. Ne dépassez pas la charge autorisée. Installation du support de montage 1U du commutateur : 1.
Chapitre 2 : Installation ATTENTION : Pour éviter d’endommager votre matériel et écarter tout risque d’électrocution : - Ne retirez pas la prise de terre car elle constitue un élément de sécurité essentiel. - Branchez le cordon d’alimentation à une prise reliée à la terre et facilement accessible à tout moment. - Coupez l’alimentation de l’unité en débranchant le cordon d’alimentation au niveau de la prise ou directement sur l’unité.
10 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Connexion d’un serveur à l’aide d’un module AVRIQ : 1. Repérez les modules AVRIQ du matériel AutoView. 2. Branchez les connecteurs clavier, moniteur et souris du câble aux voies correspondantes du premier serveur à relier au commutateur en vous aidant du code couleur. 3. Reliez une extrémité d’un câble CAT 5 au connecteur RJ-45 du module AVRIQ. 4.
Chapitre 2 : Installation 11 Dans cette configuration, l’interface OSCAR de voie locale est désactivée sur les commutateurs montés en cascade en dessous du commutateur AutoView principal. Montage en cascade de plusieurs commutateurs AutoView : 1. Connectez le commutateur AutoView en cascade à chaque serveur selon la procédure décrite à la section précédente, Installation du commutateur AutoView. 2.
12 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Utilisateur analogique A Utilisateur analogique B Commutateur AutoView 2015 Voies ARI 15 serveurs principaux Commutateur AutoView 2015 (monté en cascade) Voie ACI 16 serveurs secondaires Figure 2.
Chapitre 2 : Installation Utilisateur analogique local A Commutateur AutoView 2015 Module AVRIQ Câbles série PS/2, USB et Sun disponibles Module AVRIQ Commutateur OutLook ES Serveur 1 Commutateur AutoView 200/400 Serveur 2 Figure 2.
14 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Utilisateur analogique local A Utilisateur analogique local B Commutateur AutoView 1415/1515/2015 Serveurs secondaires Module AVRIQ Modules série, PS/2, USB et Sun disponibles Commutateur AutoView 1415/1515/2015 Serveurs secondaires Figure 2.5 : Configuration du commutateur AutoView avec des commutateurs AutoView 1415/1515/2015 NOTA : Il est possible d’utiliser des modules PS2IAC dans la figure 2.5.
Chapitre 2 : Installation 15 Ajout d’un commutateur KVM classique : 1. Montez le commutateur KVM principal sur votre étagère à rack. 2. Reliez une extrémité du câble CAT 5 à une voie disponible à l’arrière du commutateur AutoView. 3. Reliez les connecteurs du clavier, du moniteur et de la souris du module AVRIQ à une voie utilisateur du commutateur en cascade. 4. Reliez l’autre extrémité du câble CAT 5 au connecteur RJ-45 du module AVRIQ. 5.
16 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015
17 CHAPITRE 3 Opérations de base Contrôle du système par les voies analogiques Le commutateur AutoView est équipé d'un ou deux groupes de voies analogiques à l'arrière du commutateur qui vous permettent de relier un moniteur ainsi qu'un clavier et une souris PS/2 ou USB pour un accès analogique direct. Le commutateur AutoView fonctionne avec OSCAR, l’interface intuitive qui vous permet de configurer votre système et de sélectionner les serveurs.
18 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 NOTA : Vous pouvez également lancer l’interface OSCAR en appuyant deux fois de suite dans l’intervalle d’une seconde sur la touche Ctrl, sur la touche Alt, ou sur la touche Maj. Reportez-vous au chapitre Modification de l’affichage ci-après pour obtenir des détails supplémentaires. Vous pouvez utiliser cette combinaison à chaque fois que vous voyez Impr écran mentionné dans ce guide d’installation et d’utilisation.
Chapitre 3 : Opérations de base 19 Sélection du serveur précédent : Appuyez sur Impr écran, puis sur Retour arrière. Cette combinaison de touches permet de basculer entre la connexion actuelle et la connexion précédente. Déconnexion de l’utilisateur d’un serveur : Appuyez sur Impr écran puis sur Alt+0. Ceci place l’utilisateur en état libre, sans aucun serveur sélectionné. L’indicateur d’état du bureau affiche le message Libre.
20 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Tableau 3.2 : Concepts de base de la navigation dans OSCAR (suite) Touche(s) Action F1 Permet d’afficher l’aide relative à la boîte de dialogue active. Echap Permet de fermer la boîte de dialogue active sans enregistrer les modifications et d’ouvrir la dernière boîte de dialogue affichée. Dans la boîte de dialogue Principal : permet de fermer OSCAR et d’afficher l’indicateur.
Chapitre 3 : Opérations de base 21 Fonctions de configuration de l’interface OSCAR Vous pouvez configurer votre commutateur AutoView à partir de la boîte de dialogue Configuration de l’interface OSCAR. Cliquez sur le bouton Noms lors de la configuration initiale du commutateur afin d’identifier les serveurs par des noms uniques. Les autres fonctions de la boîte de dialogue Configuration permettent de gérer les tâches de routine de vos serveurs depuis l’interface OSCAR. Tableau 3.
22 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 3.2 : Boîte de dialogue Configuration (utilisateur) Figure 3.3 : Boîte de dialogue Configuration (administrateur) NOTA : La figure 3.3 s’affiche pour l’administrateur si les comptes utilisateurs locaux sont activés et pour tous les utilisateurs si les comptes utilisateurs locaux sont désactivés.
Chapitre 3 : Opérations de base 23 Figure 3.4 : Boîte de dialogue Noms NOTA : Si la liste de serveurs est modifiée, le curseur de la souris se transforme en sablier pendant que la liste est automatiquement mise à jour. Aucune opération souris ou clavier n’est acceptée tant que la mise à jour de la liste n’est pas terminée. Assignation de noms aux serveurs 1. Dans la boîte de dialogue Noms, sélectionnez un nom de serveur ou un numéro de voie et cliquez sur Modif..
24 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 NOTA : Si aucun nom n’a été attribué à un module AVRIQ, le numéro d’EID est utilisé comme nom par défaut. Attribution des types d’équipements Le commutateur AutoView détecte automatiquement les commutateurs KVM en cascade ; vous devez cependant préciser le nombre de voies du commutateur en cascade à l’aide de la boîte de dialogue Équipements.
Chapitre 3 : Opérations de base 25 Figure 3.7 : Boîte de dialogue Modif. équip. 3. Choisissez le nombre de voies prises en charge par le commutateur monté en cascade et cliquez sur OK. Si le nombre de voies souhaité n’est pas affiché, cliquez sur Autre puis saisissez un nombre de voies situé entre 4 et 24. 4. Répétez les étapes 1 à 3 pour chaque voie pour laquelle un type de dispositif doit être assigné. 5. Dans la boîte de dialogue Équipements, cliquez sur OK pour enregistrer les paramètres.
26 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Choix de l’ordre d’affichage par défaut des serveurs : 1. Sélectionnez Nom pour afficher les serveurs dans l’ordre alphabétique (par nom). -ouSélectionnez EID pour afficher les serveurs dans l’ordre numérique (par numéro EID). -ouSélectionnez Voie pour afficher les serveurs dans l’ordre numérique (par numéro de voie). 2. Cliquez sur OK. Sélection d’une combinaison de touches pour lancer l’interface OSCAR : 1.
Chapitre 3 : Opérations de base 27 Figure 3.9 : Boîte de dialogue Clavier Modification du paramètre régional du clavier : 1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Principal s’affiche. 2. Cliquez sur Config. - Clavier. La boîte de dialogue Clavier s’affiche. 3. Sélectionnez un paramètre régional de clavier et cliquez sur OK. 4. La boîte de dialogue Avertissement s’affiche afin que vous puissiez confirmer les modifications. 5.
28 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 3. Sélectionnez la langue souhaitée. 4. Cliquez sur OK pour enregistrer vos modifications. Figure 3.11 : Boîte de dialogue Langue Contrôle de l’indicateur d’état L’indicateur d’état s’affiche sur le bureau et indique le nom ou le numéro d’EID du serveur sélectionné ou l’état de la voie sélectionnée.
Chapitre 3 : Opérations de base 29 Figure 3.12 : Boîte de dialogue Indicateur Affichage de l’indicateur d’état : 1. Sélectionnez Nom ou EID pour déterminer quelle information sera affichée. 2. Sélectionnez Affiché pour que l’indicateur soit toujours affiché ou Temporisé pour que l’affichage ne dure que cinq secondes après une commutation. 3. Sélectionnez une couleur dans la zone Couleur d’affichage. 4.
30 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 lorsque la console reste inutilisée pendant un temps d’inactivité déterminé. Une fois l’économiseur d’écran activé, la console est bloquée tant que vous n’appuyez pas sur une touche du clavier ou que vous ne déplacez pas la souris. Vous devez alors saisir votre mot de passe pour continuer.
Chapitre 3 : Opérations de base 31 Protection de la console par un mot de passe : 1. Définissez le mot de passe en suivant la procédure décrite précédemment. 2. Sélectionnez Activer Écon. d’écran. 3. Spécifiez en minutes le temps d’inactivité (de 1 à 99) avant l’activation de la protection par mot de passe et le démarrage de l’économiseur d’écran. 4. Dans la zone Mode, sélectionnez Énergie si votre écran affiche le symbole ENERGY STAR® ; sinon, sélectionnez Écran.
32 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 -ouSi votre console est protégée par un mot de passe, voyez la procédure précédente, puis passez à l’étape 2. 2. Sélectionnez Activer l’écon. d’écran. 3. Spécifiez en minutes la durée du temps d’inactivité (de 1 à 99) avant activation de l’économiseur d’écran. 4. Sélectionnez Énergie si votre écran est compatible avec la norme ENERGY STAR, sinon sélectionnez Écran.
Chapitre 3 : Opérations de base 33 Désactivation de l’économiseur d’écran : 1. Dans la boîte de dialogue Sécurité, décochez la case Activer Écon. d’écran. 2. Cliquez sur OK. Activation immédiate de l’économiseur d’écran : Appuyez sur Impr écran, puis sur Pause. Affichage des informations relatives à la version L’interface OSCAR permet d’afficher les informations relatives aux versions du commutateur AutoView et du firmware des modules AVRIQ et IAC.
34 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 3.16 : Boîte de dialogue Sélec. Équip. (administrateur) 4. Sélectionnez le module AVRIQ ou IAC que vous souhaitez visualiser et cliquez sur le bouton Version. La boîte de dialogue Version Équip. s’affiche. Pour plus d’informations sur le chargement du firmware, consultez l’Annexe A. Figure 3.17 : Boîte de dialogue Version de l’équipement cible 5.
Chapitre 3 : Opérations de base 35 Figure 3.18 : Boîte de dialogue Version du firmware Désactivation d’un module AVRIQ La désactivation d’un module AVRIQ rétablit les paramètres par défaut dans les modules AVRIQ Sun, USB et PS/2 uniquement. 1. Appuyez sur Impr écran. La boîte de dialogue Principal s’affiche. 2. Cliquez sur Commandes - Affichage Version. La boîte de dialogue Version s’affiche. 3. Cliquez sur Équip. pour visualiser les informations de version relatives aux différents modules.
36 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Ajout de serveurs à la liste de balayage 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran. La boîte de dialogue Principal s’affiche. 2. Cliquez sur Config. – Balayage. La boîte de dialogue Balayage s’affiche. Figure 3.19 : Boîte de dialogue Balayage 3. Cette boîte de dialogue dresse la liste de tous les serveurs reliés à votre matériel. Cochez les cases associées aux serveurs que vous souhaitez balayer.
Chapitre 3 : Opérations de base 37 Figure 3.20 : Boîte de dialogue Commandes NOTA : La figure 3.20 représente l’écran Commandes de l’administrateur et de l’utilisateur local lorsque la case Activer Comptes utilisateurs locaux est décochée. Seuls les boutons Affichage Version, Réinitialiser équip. et Déconnexion s’affichent pour les utilisateurs à accès restreint. 3. Sélectionnez Activer le balayage dans la boîte de dialogue Commandes. 4.
38 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 La boîte de dialogue Diagnostics s’affiche. La partie supérieure de la boîte de dialogue présente les tests effectués au niveau du matériel tandis que la partie inférieure répartit les modules AVRIQ et IAC testés en trois catégories : en ligne, hors ligne et suspect. NOTA : Les modules AVRIQ et IAC peuvent apparaître hors ligne lors de leur mise à jour. Figure 3.
Chapitre 3 : Opérations de base 39 Lancement des tests de diagnostic : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran. La boîte de dialogue Principal s’affiche. 2. Cliquez sur Commandes - Lancer le diagnostic. Un message d’alerte s’affiche pour vous signaler que tous les utilisateurs vont être déconnectés. Figure 3.22 : Boîte de dialogue Alerte diagnostics 3. Cliquez sur OK pour lancer le diagnostic.
40 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 3.23 : Boîte de dialogue Diffusion NOTA : Diffusion des entrées clavier : pour que les serveurs destinataires interprètent les entrées clavier de manière identique, l’état du clavier doit être le même pour tous les serveurs. En particulier, les modes Verr Maj et Verr Num doivent être paramétrés de la même manière sur tous les claviers.
Chapitre 3 : Opérations de base 41 Figure 3.24 : Boîte de dialogue Activer diffusion 5. Cliquez sur OK pour activer la diffusion. Cliquez sur X ou appuyez sur Echap pour retourner à la boîte de dialogue Commandes. 6. Si la diffusion est activée, saisissez les données ou effectuez les mouvements de souris à diffuser à partir du commutateur. Seuls les serveurs de la liste sont accessibles. NOTA : Le deuxième utilisateur n’a pas accès aux serveurs lors de la diffusion.
42 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 3.25 : Boîte de dialogue Commutateur 3. Sélectionnez au choix le mode Préemption ou le mode Coopération comme mode de commutation. 4. Cliquez sur OK pour enregistrer les modifications. Cliquez sur la case de fermeture X ou appuyez sur Echap pour annuler.
43 CHAPITRE 4 Opérations avancées Utilisation des privilèges d’administrateur Les commutateurs AutoView 1415/1515/2015 permettent à quatre utilisateurs et un administrateur de se connecter à un même commutateur. Cet administrateur peut empêcher l’accès des utilisateurs à certains équipements depuis le menu Sécurité. Il peut également modifier, visualiser et/ou supprimer les comptes utilisateurs. Figure 4.1 : Menu Sécurité Accès à la boîte de dialogue Utilisateur (administrateur uniquement). 1.
44 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Figure 4.2 : Menu Utilisateur (administrateur uniquement) Fonctions du menu Utilisateur (administrateur uniquement) Depuis le menu Utilisateur, l’administrateur peut modifier, visualiser et/ou supprimer les comptes utilisateurs. Ce menu n’est disponible que lorsque la case Activer Compte Utilisateur est cochée dans le menu Sécurité. Les commutateurs AutoView 1415/1515/2015 comprennent quatre comptes utilisateurs standards.
Chapitre 4 : Opérations avancées 45 Figure 4.3 : Menu Modifier utilis. (administrateur uniquement) Le champ Nom utilis. affiche des noms par défaut. Ceux-ci peuvent être modifiés par l’administrateur. Les noms d’utilisateur doivent comprendre de 1 à 15 caractères. Les administrateurs peuvent également définir les mots de passe des utilisateurs dans le menu Modifier utilis. Les mots de passe doivent comprendre de 5 à 12 caractères et être composés à la fois de lettres et de chiffres.
46 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Le bouton Tout Suppr. permet à l’administrateur de refuser l’accès d’un utilisateur donné à toutes les voies plutôt que de supprimer le compte correspondant. Le bouton Tout Sélect. permet à l’administrateur d’assigner toutes les voies KVM disponibles à un utilisateur donné. NOTA : Pour enregistrer les modifications, l’administrateur doit cliquer sur OK dans le menu Utilisateur.
47 A NNEXES Annexes Annexe A : Mises à jour Flash Mise à jour du commutateur AutoView Avocent fournit un utilitaire spécifique vous permettant de mettre à jour le firmware du commutateur AutoView. Cet utilitaire configure automatiquement les paramètres de communication de la voie pour permettre un téléchargement direct depuis le serveur connecté.
48 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 • Vérifiez qu'une seconde exécution du programme ApplianceUpdate.exe n'est pas en cours. • Vérifiez que le câble utilisé est un câble série null modem. • Vérifiez dans les paramètres avancés de la voie COM que les mémoires tampon FIFO sont sélectionnées et que la mémoire tampon est définie sur Haute. ATTENTION : N’utilisez pas le serveur pendant la mise à jour, pas même pour basculer d’une fenêtre à une autre.
Annexes Figure A.
50 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Annexe B : Spécifications techniques Tableau B.
Annexes 51 Tableau B.1 : Spécifications du produit (suite) Spécifications produit du commutateur AutoView Tension nominale d’alimentation (c.a.) 100 à 240 V c.a. détection automatique Intensité nominale d’alimentation (c.a.) 0,5 A Câble d’alimentation (c.a.
52 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Annexe C : Émulation des touches avancées du clavier Sun Il est possible d’émuler certaines touches d’un clavier Sun (US) de type 5 standard en utilisant des combinaisons de touches sur un clavier PS/2. Pour activer le mode d’émulation de touches avancées du clavier Sun et utiliser ces raccourcis clavier, maintenez les touches Ctrl+Maj+Alt enfoncées, puis appuyez sur la touche Arrêt défil.
Annexes 53 Par exemple : Pour Arrêt + A, maintenez les touches Ctrl+Maj+Alt enfoncées et appuyez sur Arrêt défil, puis sur F1 + A. Ces combinaisons de touches fonctionnent avec le module AVRIQ-USB (si votre système Sun est équipé d’une voie USB) ainsi qu’avec les modules AVRIQ-VSN et AVRIQ-WSN Sun. À l’exception de la touche F12, ces raccourcis clavier ne sont pas reconnus sous Microsoft Windows. La touche F12 exécute l’activation d’une touche Windows.
54 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015 Annexe D : Assistance technique Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une difficulté, suivez les procédures ci-dessous afin de bénéficier d’une aide le plus rapidement possible. Résolution des problèmes : 1.
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
For Technical Support: www.avocent.com/support Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA Tel: +1 256 430 4000 Fax: +1 256 430 4031 Avocent International Ltd.