1. Erratic regulation, instability or hunting.
Possible Causes Remedies
A. Sticking of internal parts A. Remove internals, clean, and if necessary, replace.
B. Load changes are too quick for B. Convert to external sensing (if necessary) and install
system an ori ce or needle valve in external sensing line.
C. Oversized regulator C. Check actual ow conditions; resize regulator for min i mum
and maximum ow; if necessary, replace with smaller
regulator.
2. Erratic regulation, instability or hunting (liquid service).
Possible Causes Remedies
A. Air trapped under diaphragm A. Install valve on external sensing port and bleed off air.
(Install regulator upside down to help prevent re oc cur rence.)
3. Upstream pressure too high.
Possible Causes Remedies
A. Supply pressure is down (con rm A. Increase supply pressure.
on pressure gauge).
B. Undersized regulator. B. Check actual ow conditions; resize regulator for min i mum
and maximum ow; if necessary, replace with larger
regulator.
C. Pressure loading system pressure C1. Clean restriction or bleed ori ces.
restricted. C2. Clean lter(s).
C3. Clean loading pressure control device.
D. Faulty loading pressure control device. D. Replace/repair loading pressure control device.
It is imperative the following information be provided by the customer:
• Fluid (with uid properties)
• Range of ow rate
• Range of inlet pressure
• Range of outlet pressure
• Range of uid temperature
• Range of ambient temperature
Pressure readings should be taken at every location that pressure plays a role - i.e., regulator inlet (as close as
possible to inlet port), regulator outlet (as close as possible to outlet port), etc.
Following are some of the more common com plaints along with possible causes and remedies.