How to Guide
Sales and Specifications Sheet · CA004 · Issue Date March 2014
Heatguard
®
110-D Series–Lead Free
TYPICAL INSTALLATION
Domestic hot water distribution. To control water temperature at the source of heat (water
heater) or individual/multiple point-of-use fixtures (sinks, lavatories, or bath tubs) to provide a
safe distribution temperature
. It can also be installed at gang shower applications where the bather has no
access to the temperature adjustment means.
Heatguard®
110-D LF
ASSE 1017, ASSE 1069, ASSE 1070, CSA B125.3
Tempered Water
120°F (49°C)
Dishwasher
Hot
Water
Water Heater
Set to
140°F (60°C)
Cold
Water
Supply
SPECIFICATION DATA
Performance:
Outlet temperature range 85 – 130°F (29 – 54°C)
Factory set and locked 120°F (49°C)
Temp. hot supply 120 – 180°F (48.9 – 82.2°C)
Temp. cold supply 39 – 80°F (3.9 – 26.7°C)
Maximum pressure 230 psi (1600 kPa)
Flow rate, minimum 1 gpm (3.8 l/min)
Flow rate, maximum 20 gpm (76 l/min)
Materials:
Body Bronze
Seals EPDM
Springs Stainless Steel
Internal cap Brass
Piston Engineered Polymer
Guide tube Noryl GFN2
AVAILABLE CONNECTIONS
Sweat 1/2", 3/4" and 1"
Barb (PEX) 1/2" and 3/4"
Threaded (NPT) 1/2" and 3/4"
CPVC 1/2" and 3/4"
SharkBite 1/2" and 3/4"
CERTIFICATIONS
The Cash Acme
Heatguard
®
110-D LF
is certified to ASSE 1017, ASSE
1069, ASSE 1070, CSA B125.3, and NSF 372 and listed by Iapmo, CSA,
and ASSE for use in accordance with U.S and Canadian plumbing codes.
Note: Flow rate determined on a
Heatguard
®
110-D LF with ½” sweat fittings
2400 7th Avenue S.W. · Cullman · Alabama 35055 · USA · www.cashacme.com
US Contact: 1-877-700-4242 · sales@cashacme.com · Canadian Contact: 1-888-820-0120 · canadasales@rwc.com
A Division of Reliance Worldwide Corporation
TRIPLE LISTED!
ASSE 1017,
ASSE 1069,
ASSE 1070.