Specifications
R
&S
F
S-K40 Remote Control
Software Manual 1161.8209.42 - 04 76
Example
CALC1:MATH (TRACE1 – TRACE3
'Selects the subtraction of trace 1 from 'trace 3 in screen A
and puts the results 'in trace 1.
CALC2:MATH (TRACE2 - TRACE3)
'Selects the subtraction of trace 2 from trace 3 in screen B
and puts the results in trace 2.
Characteristics
*RST value: -
SCPI: conforming
CALCulate:MATH:STATe <Boolean>
This comman switches the mathematical relation of traces on or off.
Example
CALC:MATH:STAT ON
Characteristics
*RST value: -
SCPI: conforming
3.3.5 CALCulate:MARKer Subsystem
The CALCulate:MARKer subsystem checks the marker functions in the R&S FS-K40
option. Note that for all marker commands the suffix for the CALCulate must be 1.
CALCulate<1|2>:MARKer<1 to 4>:AOFF
CALCulate<1|2>:MARKer1:FUNCtion ZOOM <Boolean>
CALCulate<1|2>:MARKer<1 to 4>:STATe <Boolean>
CALCulate<1|2>:MARKer<1 to 4>:TRACe <numeric_value>
CALCulate<1|2>:MARKer<1>:X <numeric_value>
CALCulate<1|2>:MARKer<1 to 4>:Y <numeric_value>
CALCulate<1|2>:MARKer<1 to 4>:AOFF
This command switches off all active markers in the specified measurement
window. The window will either be “screen a” or “screen b” and will be determined
by the numeric value that follows the “CALCulate” keyword.
Example
CALC1:MARK:AOFF
’Switches off all markers in the screen A window.
Characteristics
*RST value: -
SCPI: device-specific