Specifications

R
&S
F
S-K40 Remote Control
Software Manual 1161.8209.42 - 04 75
CALCulate:LIMit<1 to 8>:UPPer:SHIFt <numeric_value>
This command moves a limit line by the indicated value in Y-direction. The line is
shifted by modifying the individual y values.
Example
C
ALC:LIM3:UPP:SHIF 20DB
' S h i f t s a l l Y v a l u e s o f l i m i t l i n e 3 b y 2 0 d B .
Characteristics
*RST value: -
SCPI: device-specific
This command is an event and is therefore not assigned an *RST value and has
no query.
CALCulate:LIMit<1 to 8>:UPPer:STATe ON | OFF
This command switches on or off the indicated limit line. The limit check is
activated separately with CALC:LIM:STAT ON.
Example
CALC:LIM4:UPP:STAT ON
'Switches on limit line 4 (upper limit)
Characteristics
*RST value: -
SCPI: conforming
3.3.4 CALCulate:MATH Subsystem
CALCulate<1|2>:MATH[:EXPression][:DEFine] <expr>
CALCulate:MATH:STATe <Boolean>
CALCulate<1|2>:MATH[:EXPression][:DEFine] <expr>
This command defines the mathematical expression for relating traces.
Parameter
<expr>::= ‘OP1 - OP2’
OP1 ::= TRACE1 | TRACE2
OP2 ::= TRACE3