Specifications

R
&S
F
S-K40 Remote Control
Software Manual 1161.8209.42 - 04 72
CALCulate:LIMit<1 to 8>:TRACe < numeric_value >
This command assigns a limit line to a particular trace..
Examples:
“CALC:LIM2:TRAC
'Assigns limit line 2 to the trace 1.
Characteristics
*RST value: 1
SCPI: device-specific
3.3.3.2 CALCulate:LIMit:CONTrol Subsystem
The CALCulate:LIMit:CONTrol subsystem defines the x-axis (CONTrol-axis).
CALCulate:LIMit<1 to 8>:CONTrol[:DATA] <numeric_value>,<numeric_value>
CALCulate:LIMit<1 to 8>:CONTrol:SHIFt <numeric_value>
CALCulate:LIMit<1 to 8>:CONTrol[:DATA] <numeric_value>,<numeric_value>
This command defines the X-axis values (frequencies) of the upper or lower limit lines.
The number of values for the CONTrol axis and for the corresponding UPPer
and/or LOWer limit lines have to be identical. Otherwise default values are entered
for missing values or unnecessary values are deleted.
Example
CALC:LIM2:CONT 1MHz,30MHz,100MHz, 300MHz,1GHz
'Defines 5 reference values for the X-axis of limit line 2
CALC:LIM2:CONT?
'Outputs the reference values for the X-axis of limit line 2
separated by a comma.
Characteristics
*RST value: -
SCPI: conforming
CALCulate:LIMit<1 to 8>:CONTrol:SHIFt <numeric_value>
This command moves a limit line by the indicated value in x direction. The line is
shifted by modifying the individual x values.
Example
CALC:LIM2:CONT:SHIF 50KHZ
' S h i f t s a l l r e f e r e n c e v a l u e s o f l i m i t l i n e 2 b y 5 0 k H z .
Characteristics
*RST value: -
SCPI: device-specific
T h i s c o m m a n d i s a n e ve n t a n d is t h e re f o r e no t a s s i g n e d a n * R S T v a l u e a n d h a s n o q ue r y .