Specifications

R
&S
F
S-K40 Remote Control
Software Manual 1161.8209.42 - 04 68
Example
CALC:EVAL 0
'Specifies that residual noise is calculated over the entire
trace
Characteristics
*RST value: 0
SCPI: device-specific
CALCulate<1|2>:EVALuation:STARt
This command specifies the start frequency for residual noise calculation when
CALCulate<1|2>:EVALuation[:STATe] is switched ON. This command has no
effect if CALCulate<1|2>:EVALuation[:STATe] is switched OFF
Example
CALC:EVAL:STARt 1MHZ
'Specifies that residual noise is calculated starting from 1
MHz
Characteristics
*RST value: 1 KHz
SCPI: device-specific
CALCulate<1|2>:EVALuation:STOP
This command specifies the stop frequency for residual noise calculation when
CALCulate<1|2>:EVALuation[:STATe] is switched ON. This command has no
effect if CALCulate<1|2>:EVALuation[:STATe] is switched OFF
Example
CALC:EVAL:STOP 1 MHZ
Specifies that residual noise is calculated up to 1 MHz
Characteristics
*RST value: 1 MHz
SCPI: device-specific
3.3.3 CALCulate:LIMit Subsystem
The CALCulate:LIMit subsystem consists of the limit lines and the corresponding limit
checks. The limit lines can be defined as upper or lower limit lines. The individual Y
values of the limit lines correspond to the values of the X-axis (CONTrol). The number
of X- and Y-values must be identical.
Up to 8 limit lines can be defined at the same time (marked by LIMIT1 to LIMIT8) in the
screen