Specifications

46 DataMan 8000 Quick Reference Guide DataMan 8000 Quick Reference Guide 47
Weight 326 g
Operating Temperature 0ºC — 40ºC (32ºF — 104ºF)
Storage Temperature -40ºC — 60ºC (-40ºF — 140ºF)
Maximum Humidity 95% (non-condensing)
Codes Data Matrix
TM
; QR Code and microQR Code; UPC/EAN/JAN;
Codabar, Interleaved 2 of 5, Code 39, Code 128, and Code
93, Pharma, Postal, RSS/CS, PDF 417, MicroPDF 417
Power Supply
Requirements
DataMan 8100 with USB (USB BUS powered or external
2.5 W maximum LPS or NEC class 2 power supply): +5V
- +6V DC
DataMan 8500 with USB (external 2.5 W maximum LPS
or NEC class 2 power supply is required): +5V - +6V DC
DataMan 8100/8500 with RS-232 (external 5.0W maximum
LPS or NEC class 2 power supply): +4.75V - +6.0V DC (2.5
m RS-232 cable), +5.5V - +6.0V DC (5.0 m RS-232 cable)
DataMan 8100/8500 with Ethernet (Class 2 PoE supply):
6.0W maximum
Battery life for wireless
reader (typical use case)
2900 triggers can be operated within a 10 hour working shift
Wireless protocol 802.11 b/g, 2.4 GHz, User Selectable channels 1-11
DataMan 8000 Specications DataMan Base Station Specications
Weight 328 g
Operating Temperature 0ºC — 40ºC (32ºF — 104ºF)
Storage Temperature -40ºC — 60ºC (-40ºF — 140ºF)
Maximum Humidity 95% (non-condensing)
Power Supply
Requirements 24V -+ 10%, 13 W maximum LPS or NEC class
2 power supply, or PoE class 3