Specifications
X723-300151 5-23 Issue 2
(CCEMA) Alarm event | Route alarms | Extern relays | Card out >A
enter start stream, start circuit >P3, A1
config. options 1-14 (U = unassigned) >
(P3, cct A1) alarm config Unassigned >
(P3, cct A2) alarm config 4 >
(P3, cct A3) alarm config Unassigned >
(P3, cct A4) alarm config Unassigned >5
(CCEMA) Alarm event | Route alarms | Extern relays
*
> | Card out >A
PCM streams for Dual G.703 LIU cards in port 1 and 2 should be entered
as S1 for Port 1 Line 1, S2 for Port 1 Line 2, S3 for Port 2 Line 1, and S4
for Port 2 Line 2. Other channel cards e.g. Dual Nx64 LIU should be
entered as P1, A1 for Port 1 circuit 1, P1, A2 for Port 1 circuit 2 etc.
Display Format
(CCED) Port | sYnc | Alarms | Cross connect >A
(CCEDA) Alarm event | Route alarms | Extern relays | Card out >A
S2, alarm config 1
S3, alarm config 8
S4, alarm config 4
P3, cct A2 alarm config 4
P3, cct B2 alarm config 5
The display option will list all sources of alarm events that are currently
assigned.
With the alarm event triggers set in the configuration, the operator must
then 'Enable' the alarm events before they will function.
(CC) Current | Run | Edit | Alarm event >A
(CCA) Enable | Disable | Status >E
To disable alarm events so that a change of PCM status does not cause a
configuration change, the 'Disable' menu option should be selected.
(CCA) Enable | Disable | Status >D
In order to check the current alarm event mode, the 'Status' option may be
selected.
(CCA) Enable | Disable | Status >S
alarm events currently disabled.