Specifications

X723-300151 5-20 Issue 2
Up to 31 timeslots may be selected and timeslots which are already
connected will be shown as 'Duplex'. To disconnect an allocated timeslot
enter U.
MULTIPOINT
Selecting multipoint operation is exactly the same as ‘Duplex’ except that
the timeslots are also allowed to pass through from Line 1 to Line 2 in
duplex as well as being dropped/inserted to the relevant stream on the
cross connect switch. The timeslot fromthe switch is multipointed
(logically ‘ANDed’) with the through timeslot from the other line. The
display will show ‘Multipoint’ instead of ‘Duplex’.
Display Format
This command allows the display of all of the parameters set above.
(CCED) Port | sYnc | Alarms | Cross connect >P
(CCEDP) Assigned cct | Circuit ctl | Smart configs | p1 | p2 | p3 | p4 >1
(CCEDP1) sYnc | F code | Bypass | Mode | Error | cRc4 | Alarm | Ts assign >
Each parameter may be selected for display only - no changes are possible.