Specifications

X723-300151 6-16 Issue 2
Timeslot local loop
This commands the system controller to loop a selected timeslot back to
its source via the cross connect switch.
(MD) Set | Display | Loops | Reconfigure >L
(MDL) Local | Incoming | Timeslot local | Circuits >T
stream, timeslot >P3,1
When applying a timeslot local loop all data sourced from the looped
timeslot will be forced to fault codes. For Nx64k circuits, all timeslots
must be looped individually.
Circuit Loop
This command instructs channel cards supporting circuit loops to activate
or clear the loop. For details of loops provided on individual channel
cards, refer to the channel card operating manual for details. Individual
circuit loops may be set and cleared.
(MD) Set | Display | Loops | Reconfigure >L
(MDL) Local | Incoming | Timeslot local | Circuits >C
(MDLC) Set | Clear >S
port, circuit >P3,A2
(MDLC) Set | Clear
*
>