Specifications

X723-300151 6-13 Issue 2
Circuit Status
This menu command requests a port followed by the circuit range, and
then displays any timeslot assignments followed by the status port values
for the range specified.
(MC) sYnc | cOnfig | Alarms | Circuit status | Smart configs >C
port, first, last cct >P3,A1,A4
port (P3, A1,TS 4) status 1 11011111B, status 2 10011111B
port (P3, A2,TS 5) status 1 11111111B, status 2 10111111B
port (P3, A3,TS ) status 1 11111101B, status 2 11011111B
port (P3, A4,TS 7) status 1 10111111B, status 2 11011111B
Refer to the relevant interface card Reference manual for the
interpretation of status port byte information.
Smart Channel Card Configuration Storage
The operator may list the current storage in use for smart channel card
configurations. A Smart card may have up to 4 configurations, but if any
are the same these will only count as 1 config. Dual LIU cards in ports 1
and 2 will have 14 integrated configurations.
(MC) sYnc | cOnfig | Alarms | Circuit status | Smart configs >S
remaining storage = 86%
P1 position A DT310 allocated 14 configs.
P4 position A DT580 allocated 2 configs.
6.2.2 Setting Data and Signalling
(M) Current | Data tests | self Test | Alarms | Version | System | typE >D
The timeslot data and signalling can be set on the outgoing timeslots of all
streams and ports from the cross-connect awitch. Data may be set in
binary, decimal or hexadecimal with suffix B,D or H added as appropriate.
If the suffix is omitted decimal will be assumed.
(MD) Set | Display | Loops | Reconfigure >S
(MDS) Data | Signalling >D
stream, timeslot, data >P3,1,70H