Specifications

X723-300151 6-6 Issue 2
No. FAULT RELAYS LEDS ACTIONS N
SMAISNO
PSY RFI6ITCT
SAASAGSSE
SMART GROUP 6 LINE 2
32 Line loss * * 2 3 * * * * 7 3
33 AIS * 2 3 * * * * 8 3
34 F sync loss * * 2 3 * * * * 9
35 Filt err 10
-3
** 23 ** **93
36 Tslt 16 AIS * 2 3 * * 10 3
37 MF sync loss * * 2 3 * * 10 3
38 MF Remote Alarm * 2 3 * 16 3,9
39 Frame slip * * 2 3 10 3
40 Remote alarm * 2 3 16 3
41 Low err rate * 2 3 15 3
44 Line O/P Fail * * 2 3 7 3
45 cRc reframe * * 2 3 9
46 Local loop * 2 3 12
47 Incoming loop * 2 3 * * 12
48 Circuit inhibit 0
SMART GROUP 6 MISC
31 System Restart * * * 2 3 5 3
30 Unconfigured * * * 2 3 * * * * 5 3
25 Self Test Fail * * * 2 3 * * 6 3
23 Bypass * 2 3 * * 12 3
22 Clock Bypass * 2 3 * * 12 3
55 Path A selected 0
54 Path B selected 0
SYNC GROUP 7
1 Not primary sync * * 6 8 7
2 Sync 2 failed * 1 14
3 Sync 3 failed * 1 14
4 Sync 4 failed * 1 14
5 No sync source * * * 1 14
CIRCUIT GROUP 8
1 Alarm 1 * * * 2 3 4 5 8 6 4
2 Alarm 2 * 2 3 4 5 11 4
3 Slip * 2 3 4 5 12 4
4 Loop * 1 15
5 Alarm inhibit 0