Specifications
X723-300151 6-3 Issue 2
Inhibit
(FA) List | list All | Circuit alarms | Received attention >C
(FAC) List | Enable | Inhibit >I
port, circuit >P3,B4
List
(FA) List | list All | Circuit alarms | Received attention >C
(FAC) List | Enable | Inhibit >L
P3 circuit B4 alarm inhibited
Enable
(FA) List | list All | Circuit alarms | Received attention >C
(FAC) List | Enable | Inhibit >E
port, circuit >P3,B4
The alarm inhibit function derives information from the equipment map,
and will warn the operator if an inhibit is attempted on a card that is not
installed (Non-installed cards are not monitored for faults).
Installing or removing a card from the equipment map will clear any
circuit inhibits set for that card.
6.1.5 Received Attention
Menu commands are available to enable the operator to clear the alarm
relay response of any currently active faults. Active faults are marked
with the 'Ocrd' (Occurred) status. When 'Received attention' is
implemented this will change to 'RxAt'.
(FA) List | list All | Circuit alarms | Received attention >R
(FAR) Faults | Smart faults | p1 | p2 >
System faults may be marked received attention with the 'Faults' menu
command.
(FAR) Faults | Smart faults | p1 | p2 >F
P63, 2 RxAt, 5 System , 9 Config 1 , , , TS , Time 18,6, 13, 28
P63, 2 RxAt, 9 Misc , 3 Map mismatch , , , TS , Time 21,4, 14, 32
(FAR) Faults | Smart faults | p1 | p2
*
>
All faults which have received attention will be displayed.
Actioning this command will log a 'Rx.Attention Local' fault into the fault
store.