Specifications
X723-300151 6-2 Issue 2
6.1.1 Fault Logging Modes
The operator can display or change the current fault reporting mode by
menu selection:
'Off' - faults will be stored in the fault buffer.
'Logging' - faults will be logged to the screen as they occur as well as being
stored.
'ASR' (Alarm Service Request)- An audible sound will be emitted from the
terminal at one minute intervals as well as the faults being stored.
(F) Mode | Store | Active | sTats >M
(FM) Off | Logging | Asr | Current >C
current mode = 2 - Asr
(FM) Off | Logging | Asr | Current
*
>
6.1.2 Fault Store Listing and Clearance
The operator may 'List' all faults in the store, 'list New' faults since the
last listing or 'Clear' the store completely. The fault store can hold up to
64 faults.
(F) Mode | Store | Active | sTats >S
(FS) Clear | List | list New >
6.1.3 Displaying Active Faults
The operator may list the active faults within any or all of the fault
groups. The 'List' option will prompt for the required group whilst the 'list
All' will display active faults within all groups except faults on cards not
mapped in.
(F) Mode | Store | Active | sTats >A
(FA) List | list All | Circuit alarms | Received attention >L
(FAL) p1 | p2 | sysTem | mAnagement | sYnc | Smart | Circuits | Misc >
6.1.4 Inhibiting Circuit Alarms
The operator may modify each circuit to inhibit its alarm response and
fault logging. To check which have been modified in this way, a list option
provides a display of circuits that have been inhibited.
Note that if a circuit is set to alarm inhibit, then a single active fault will
exist for that circuit indicating the mode set.