Specifications

X723-300151 5-36 Issue 2
Cards must be removed from the equipment map in order to clear the map
mismatch fault after a card has been removed from the chassis. If a card
is fitted, but is not installed in the equipment map for that card slot, a
map mismatch fault will not be raised and fault logging from that card
will be inhibited.
Listing Current Map
(C) Channel | Management | Link | Status | Equipment map >E
A list of all cards mapped in or fitted is obtained by selecting 'List'.
(CE) List | Install | install All | Remove | iDent >L
Card Position Map Fitted
P1,A DT310 DT310
P2,A none none
P3,A none DT310
P3,B none none
P3,C none none
P3,D DT575 DT575
P3,E none none
P3,F none none
P4,A DT530 none
P4,B none none
P4,C none none
P4,D none none
P4,E DT579 DT579
(CE) List | Install | install All | Remove | iDent
*
>
The above mapping will cause a 'Map mismatch' alarm due to P4,A
Installing a Card
(CE) List | Install | install All | Remove | iDent >I
select port, card >P3,A
DT310 installed
(CE) List | Install | install All | Remove | iDent
*
>
Note: Installing a smart channel card in the equipment map will re-
initialise the card.