Specifications
34 | Page
2‐4‐3CONTROLLER&PTZSetup
TocontrolthePTZfunctionsofthecamera,connectacontrollertotheRS‐485port.
① ConnecttheRS‐485cablesofthePTZcameratotheRS‐485portontherearpanel.
② PressthePTZmenubutton.ThenPTZmenuscreenisdisplayedasbelow.
Figure3.4.4.PTZControlSetupScreen
Note: For speed dome camerasthat support RS‐485, connect them directly to theRS‐485 port. If the camera is
controlledwithRS‐232C,useaRS‐485toRS‐232Csignalconverter.
OnthePTZcontrolsetupscreen,youcanselect
orsettheprotocoltypeofthecamerathatisthesameastheone
installedonthesite.IfthecamerahasaspecificcameraID,selectthecameraIDusingthemouseorthecontrol
buttonoftheremotecontrol.
ThefollowingoptionsareavailableonthePTZsetup
screen.
CHANNEL(ChannelnumberthatthePTZisconnectedto)
NAME(Protocoltype)
SPEED(BaudRate)(19200,14400,9600,4800,2400)
ID(0‐63)