User's Manual

900 MHz Recommended Frequencies
The following are the 3 non-overlapping channels that are recommended:
906 MHz
915 MHz
924 MHz
NETWORKING INFORMATION
The Cyclone access point module will each utilize an IP address on the operator’s network. It is
recommended that the access point modules never be placed directly onto the Internet. IP
addresses may be assigned sequentially clockwise around an access point cluster for easier
manageability. The operator will also need to identify the appropriate subnet mask and network
gateway each of the modules.
LIGHTNING PROTECTION
The Cyclone access point module, cluster management module, and GPS antenna must be
mounted at least 2 feet below the highest point at the site for lightning strike mitigation. It is
highly recommended that the site have a lightning protection system installed. Ensure the
location is properly grounded for lightning protection according to all applicable national and local
codes. To protect operator equipment from surges on the Ethernet cable that is connected to the
Cyclone System, the Cyclone surge suppressor must be used.
ELECTRICAL REQUIREMENTS
Specifications for the voltages and distance can be found in the Specification section of this
manual. Make certain the installation conforms to the National Electrical Code (NEC), country
and local codes. If uncertain of code requirements, obtain the services of a licensed electrician.
DES ENCRYPTION
DES (Data Encryption Standard) is a secret key encryption scheme. The basics of DES are that it
performs a series of bit permutations, substitutions, and recombination operations on blocks of
data utilizing a secret key. On the Cyclone system, DES encryption of the over the air link is done
on a per access point module or backhaul timing master module basis and does not affect the
performance or throughput of the system. The Cyclone modules contain unique factory
programmed secret keys to establish the encrypted link.
INSTALLATION
The following steps are required to install the Cyclone module:
1. Unpack the Cyclone products
2. Configuration of the modules
3. Installation of the modules
4. Alignment
UNPACK THE CYCLONE PRODUCTS
Upon receipt, carefully inspect all shipping boxes for signs of damage. If there is damage,
immediately notify the transportation company. Unpack equipment, making sure that all ordered
components have arrived. It is recommended that you save all the packing materials. They can
be used for transportation of the equipment to and from installation sites.
CONFIGURATION OF THE AP
In all cases, when a configuration parameter is modified, the change must be saved and the
module must be rebooted