User's Manual Part 3

Release8OperationsGuide
Issue2,November2007 Draft5forRegula toryReview 380
You can configure the module such that, when it senses the override plug, it responds by
either
resetting the LAN1 IP address to 169.254.1.1, allowing access through the
default configuration without changing the configuration, whereupon you will be
able to view and reset any non-default values as you wish.
resetting all configurable parameters to their factory default values.
Acquiring the Override Plug
You can either purchase or fabricate an override plug as follows. To purchase an
override plug for a nominal fee, order the plug at
http://www.best-tronics.com/Last Mile Gear.htm
. To fabricate an override plug, perform
the following steps.
Procedure 36: Fabricating an override plug
1. Install an RJ-11 6-pin connector onto a 6-inch length of CAT 5 cable.
2. Pin out all 6-pins.
3. Short (solder together) Pins 4 and 6 on the other end. Do not connect any other
wires to anything. The result should be as shown in Figure 140.
end of procedure
Pin
1 white / orange Pin 1
Pin 2 white / green Pin 2
Pin 3 white / blue Pin 3
Pin 4 green Pin 6
Pin 5 blue Pin 5
Pin 6 orange Pin 4
Figure 140: RJ-11 pinout for the override plug
Using the Override Plug
IMPORTANT!
While the override plug is connected to a module, the module can neither
register nor allow registration of another module.
To regain access to the module, perform the following steps.