User's Manual Part 3

Release8InstallationandConfigurationGuide
Issue2,November2007 Draft5forRegula toryReview 342
CAUTION!
Failure to set the 115-/230-volt switch correctly can result in damage to
equipment.
IMPORTANT!
The AC power connectors are labeled N for Neutral, L for Line, and PE for
Protective Earth (PE)
or ground. The maximum thickness of wire to be used is
4 mm
2
or
12 AWG.
7. Route the Ethernet cables from the APs and or BHs to the CMM2.
The strain relief plugs on the CMM2 have precut holes. Each hole of the strain
relief is designed to hold two CAT 5 UTP cables or one shielded cable. The
Ethernet cables have RJ-45 (standard Ethernet) connectors that mate to
corresponding ports inside the CMM2.
These ports are labeled J3. Eight J3 ports are available on the CMM2 to
accommodate any combination of APs and BHs.
The logical connections in the CMM2 are displayed in Figure 124.