User's Manual Part 3
Release8InstallationandConfigurationGuide
Issue2,November2007 Draft5forRegulatoryReview 303
18.4.3 RadioTaboftheBHM
An example of the Radio tab in a BHM is displayed in Figure 102.
Figure 102: Radio tab of BHM, example
In the Radio tab of the BHM, you may set the following parameters.
Radio Frequency Carrier
Specify the frequency for the BHM to transmit. The default for this parameter is None.
(The selection labeled Factory requires a special software key file for implementation.)
In a 5.7-GHz BHM, this parameter displays both ISM and U-NII frequencies. In a 5.2-GHz
BHM, this parameter displays only ISM frequencies. For a list of channels in the band,
see Considering Frequency Band Alternatives on Page 136.
Color Code
Specify a value from 0 to 254. For registration to occur, the color code of the BHM and
the BHS must match. On all Cyclone modules, the default setting for the color code value
is 0. This value matches only the color code of 0 (not all 255 color codes).