SM Power Up Mode With No 802.3 Link
Specify the default mode in which this BHS will power up when it senses no Ethernet link.
Select either
• Power Up in Aim Mode—the BHS boots in an aiming mode. When the BHS
senses an Ethernet link, this parameter is automatically reset to Power Up in
Operational Mode. When the BHS senses no Ethernet link within 15 minutes
after power up, the BHS carrier shuts off.
• Power Up in Operational Mode—the BHS boots in Operational mode and
attempts registration. Unlike in previous releases, this is the default selection in
Release 8.
2X Rate
See 2X Operation on Page 90.
Frame Timing Pulse Gated
If this BHS extends the sync pulse to a BHM or an AP behind it, select either
• Enable—If this BHS loses sync, then do not propagate a sync pulse to the BHM
or AP. This setting prevents interference in the event that the BHS loses sync.
• Disable—If this BHS loses sync, then propagate the sync pulse anyway to the
BHM or AP.
See Wiring to Extend Network Sync on Page 374.
The General tab also provides the following buttons.
Save Changes
When you click this button, any changes that you made on the Configuration page are
recorded in flash memory. However, these changes do not apply until the next reboot of
the module.
Reboot
When you click this button
1. the module reboots.
2. any changes that you saved by a click of the Save Changes button are
implemented.