Figure 162: Calculated Frame Results section of Frame Calculator tab, example
5. Record the value of the Uplink Rcv SQ Start field.
6. Scroll up to the Scheduling parameter.
7. Select Hardware.
8. Click the Apply Settings button.
RESULT: The values in the Calculated Frame Results section are updated for
hardware scheduling.
9. In the Number Control Slots parameter, type in the number needed.
10. Click the Apply Settings button.
11. Click the Calculate button.
12. Scroll down the tab to the Calculated Frame Results section. If “Invalid
Configuration” is displayed, check and change values and settings, with special
attention to the Platform Type parameters (P7, P8, and so on).
13. Record the value of the Uplink Rcv SQ Start field.
14. If the recorded values of the Uplink Rcv SQ Start field are within 150 time bits of
each other, skip the next step.
15. Repeat this procedure, changing the value of the Downlink Data parameter until
the values that this tool calculates for the Uplink Rcv SQ Start field are within
150 time bits of each other regardless of the selection in the Scheduling
parameter.