User's Manual Part 3

Release8OperationsGuide
Issue2,November2007 Draft5forRegula toryReview 447
Downlink Data
Initially set this parameter to the same value that the AP has for its Downlink Data
parameter (percentage). Then, as you use the Frame Calculator tool in Procedure 41,
you will vary the value in this parameter to find the proper value to write into the
Downlink Data parameter of all APs in the cluster.
High Priority Uplink Percentage
If the AP is running Cyclone software earlier than Release 8, set this parameter to
the current value of the High Priority Uplink Percentage parameter in the AP.
Total Number UACK Slots
If the AP is running Cyclone software earlier than Release 8, set this parameter to
the current value of the Total NumUAckSlots parameter in the AP.
Number High
If the AP is running Cyclone software earlier than Release 8, set this parameter to
the current value of the Num High parameter associated with Total NumUAckSlots
in the AP.
Number DACK Slots
If the AP is running Cyclone software earlier than Release 8, set this parameter to
the current value of the NumDAckSlots parameter in the AP.
Number High
If the AP is running Cyclone software earlier than Release 8, set this parameter to
the current value of the Num High parameter associated with NumDAckSlots in the AP.
Number Control Slots
Set this parameter to the current value of the Control Slots (for Release 8) or
NumCtlSlots (for earlier releases) parameter in the AP. In Release 8, the Control Slots
parameter is present in the Radio tab of the Configuration web page.
Number High
If the AP is running Cyclone software earlier than Release 8, set this parameter to
the current value of the Num High parameter associated with NumCtlSlots in the AP.
To use the Frame Calculator, perform the following steps.
Procedure 41: Using the Frame Calculator
1. Populate the Frame Calculator parameters with appropriate values as described
above.
2. Click the Apply Settings button.
3. Click the Calculate button.
4. Scroll down the tab to the Calculated Frame Results section.
NOTE: An example of the Calculated Frame Results section is displayed in
Figure 162.