User's Manual Part 2

Release8InstallationandConfigurationGuide
Issue2,November2007 Draft5forRegulatoryReview 295
See Overriding Forgotten IP Addresses or Passwords on AP, SM, or BH on Page 379.
The Unit Settings tab also contains the following buttons.
Save Changes
When you click this button, any changes that you made on all tabs are recorded in flash
memory. However, these changes do not apply until the next reboot of the module.
Undo Unit-Wide Saved Changes
When you click this button, any changes that you made in any tab but did not commit by
a reboot of the module are undone.
Set to Factory Defaults
When you click this button, all configurable parameters on all tabs are reset to the factory
settings.
Reboot
When you click this button
1. the module reboots.
2. any changes that you saved by a click of the Save Changes button are
implemented.
18.3 SETTINGTHECONFIGURATIONSOURCE
The AP includes a Configuration Source parameter, which sets where SMs that register
to the AP are controlled for MIR, VLAN, the high-priority channel, and CIR as follows.
The Configuration Source parameter affects the source of
all MIR settings:
Sustained Uplink Data Rate
Uplink Burst Allocation
Sustained Downlink Data Rate
Downlink Burst Allocation
all SM VLAN settings:
Dynamic Learning
Allow Only Tagged Frames
VLAN Ageing Timeout
Untagged Ingress VID
Management VID
VLAN Membership
the Hi Priority Channel setting
all CIR settings
Low Priority Uplink CIR
Low Priority Downlink CIR
Hi Priority Uplink CIR
Hi Priority Downlink CIR
Most operators whose plans are typical should consult Table 45.