User's Manual Part 1
Release8OverviewofCycloneNetworks
Issue2,November2007 Draft5forRegulatoryReview 110
Monitoring Features
Module
Type(s) Controlled in GUI Page/Tab
SNMP
Control
List of registered SMs/BHSs with full data,
with hot links to SMs/BHSs
AP BHM Configuration/General
multiple
objects
Abbreviated list of SMs/BHSs, with hot links
to SMs/BHSs
AP BHM Configuration/General
multiple
objects
Received power level indication All radios Configuration/General yes
LEDs on modules to display states and
activity
All modules no no
Received interference level indication (jitter) All radios Configuration/General yes
Configurable web-page auto-refresh All modules Configuration/General yes
SM registration failures AP BHM Statistics/Reg Failures yes
Event log All modules Home/Event Log no
Operator can use own logo on GUI pages All modules no yes
Operator can use own style sheets for GUI All modules no yes
Bridge Management Features
Module
Type(s) Controlled in GUI Page/Tab
SNMP
Control
Configurable bridge entry timeout All radios Configuration/General yes
Bridging table statistics (up to 4096 entries) All radios Statistics/Bridging Table yes
Disable bridging on BHs BHM BHS Configuration/General yes
SM Isolation Features (preventing
communication between SMs)
Module
Type(s) Controlled in GUI Page/Tab
SNMP
Control
SM isolation at AP AP Configuration/General yes
SM isolation at CMM CMMmicro Configuration/General yes
SM Isolation Features
Module
Type(s) Controlled in GUI Page/Tab
SNMP
Control
Translation bridging (replace customer MAC
with SM MAC address)
AP Configuration/General yes
With Translation bridging, choice of sending
untranslated ARP
AP Configuration/General yes
Translation table statistics All radios Statistics/Translation Table yes
Quick Start Feature
Module
Type(s) Controlled in GUI Page/Tab
SNMP
Control
AP configuration quick-start wizard AP BHM Quick Start