Third Party Verification Claim
Report No.: 3173-22005 Page 7 of 9
Primary Regulation: California Appliance Efficiency Regulations
Test Results: All tests and evaluations were conducted per the written procedures specified in the
Regulation and its reference standard.
California Appliance Efficiency Regulations
Section 1605.3 (h) Plumbing Fittings
(1) Tub Spout Diverters – COMPLIED
The leakage rate of the tub spout diverter was not greater than the applicable values shown in
Table H-3 when tested in accordance with Sections 5.3.6 and 5.6.1.5 of ASME A112.18.1-
2012/CSA B125.1-12.
Finding: Water Temperature Used for Testing: 95 °F
Model No.
Measured Leakage Rate at 10 psi
Automatic
Reset
Type
Remained
functional and
reset itself to tub
spout position
When New
(Max Allowed: 0.01 gpm)
After 15,000 Cycles
(Max Allowed: 0.05 gpm)
WF-
W98103H
0
0
NO
NA
(5) Showerheads –COMPLIED
The flow rate of the showerhead / handheld shower / body spray was not greater than 1.8 gpm at
80 ± 1 psi flowing pressure and met the minimum requirements (not less than 60% of
manufacturer’s specified maximum flow rate at 20 ± 1 psi and not less than 75% at 45 and 80 ± 1
psi) as shown in Table H-5 when tested in accordance with 10 C.F.R. Section 430.23(t) (Appendix
S to Subpart B of part 430) and Section 5.12 of ASME A112.18.1-2018/CSA B125.1-18.
Finding: Water Temperature Used for Testing = 100 °F
Model No.
Mode
Mfr’s
Specified
Max Flow
Rate
(gpm)
Measured Flow Rate
(gpm)
Minimum Flow Rate
(Percentage of Mfr’s
Specified Maximum Flow
Rate)
20 psi
45 psi
80 psi
20 psi
45 psi
80 psi
DB-W93102H-
10
showerhead
1.8
1.52
1.46
1.37
84.44
81.11
76.11
Handshower
1.33
1.73
1.79
73.89
96.11
99.44
WF-
W98C02CP-10
showerhead
1.8
1.74
1.54
1.49
96.67
85.56
82.78
Handshower1
1.11
1.45
1.53
61.67
80.56
85.00
DB-98102LSJ-
10
showerhead
1.8
1.41
1.45
1.58
78.33
80.56
87.78
Handshower1
1.16
1.69
1.61
64.44
93.89
89.44
WF-W98103H
showerhead
1.8
1.52
1.46
1.37
84.44
81.11
76.11
Handshower1
1.33
1.73
1.79
73.89
96.11
99.44