Operating instructions
Page 8 of 16 Installation and Operating Instructions SC-411HS-20
4/1/14 CP5122A
Option Set 1
(Input polarity, timed override, sweep/intersection, auto siren)
S1 (CUTOUT Input), S2 (SIRCTRL Input), S3 (LITCTRL Input) - These
inputs are normally activated by a 12V input (ON). Press the button once
until it FLASHES to change to ground activation. Press the button again
for OFF to disable.
S4 (Timed Override) - While the siren mode in Wail, Yelp or Phaser,
momentarily pressing the Manual button will override the Wail, Yelp or
Phaser tone. With this option ON the unit automatically goes back to the
previous tone after 10 seconds.
S5 (Sweep/Intersection Function) - While the siren mode is in Wail, Yelp,
or Phaser, momentarily activating the siren control input (SIRCTRL) will
change the unit into sweep mode, where the tone automatically changes
every few seconds. Press again to triple the change rate (intersection
mode). Press again to go back, or press twice to cancel.
S6 (Automatic Siren) An Automatic Siren feature turns on the siren in the
Wail mode when Primary button 3 is on.
Press the DIM button momentarily to move into next section, or DIM for 3
seconds to save & exit.
Option Set 2
(Tone enables, short manual, primary progression)
S1 (Two-Tone Enable) - Two-Tone replaces Phaser tone when ON.
S2 (Phaser Enable) - Phaser (or Two-Tone) is disabled and replaced with
Yelp when OFF.
S3 (Short Manual Enable) - The Manual siren tone will normally die out
and stop when the Manual button is released. Turning option ON forces
the Manual siren tone to stop immediately upon release.
S4 (Horn Enable) - Horn tone is disabled when turned OFF.
S5 (Progressive Primary) - As the Primary buttons are moved from off to
position 3 outputs 1 and 2 stay on. Turn this option OFF For isolated
operation, where each output is independent.
S6 (Non-Progressive Override) - With Progressive Primary option off,
turning this option ON will turn on all 3 outputs when Primary button 3 is
active. Otherwise there is no effect.
Press the DIM button momentarily to move into next section, or DIM for 3
seconds to save & exit.
S1 S2 S3 S4 S5 S6 BUTTON
CUTOUT
Polarity
SIRCTRL
Polarity
LITCTRL
Polarity
Timed
Override
Sweep /
Intersection
Automatic
Siren
FUNCTION
ON - Pos
Blink - Neg
OFF -
Disable
ON - Pos
Blink - Neg
OFF -
Disable
ON - Pos
Blink - Neg
OFF -
Disable
OFF
ON
OFF
ON
ON
OFF
OPTIONS
(Top is
default)
S1 S2 S3 S4 S5 S6 BUTTON
TWO-
TONE
PHASER
Enable
Short
MANUAL
HORN
Enable
Progressive
Primary
Non-
Progressive
Override
FUNCTION
OFF -
Phaser
ON -
Two-Tone
ON -
Phaser
OFF -
Disable
(Yelp)
OFF -
Normal
Manual
ON - Short
Manual
ON - Horn
Enabled
OFF -
Disabled
ON -
Progressive
Primary
Operation
OFF - Non-
Progressive
Operation
OFF -
Normal
Progression
ON - Non-
Progressive
Override
OPTIONS
(Top is
default)
1
2
Primary button 1 light blinking
Momentarily press button
S1 - S6 to change.
Primary button 2 light blinking
Momentarily press button
S1 - S6 to change.
CUTOUT
Polarity
LITCTRL
Polarity
Sweep/
Intersect
SIRCTRL
Polarity
Timed
Override
Automatic
Siren
TWO-
TONE
Short
MANUAL
Prog
Primary
PHASER
Enable
HORN
Enable
Non-Prog
Override