Specifications



SC-10 02-10 14
VoluntEEr
SC-10 12-10 14
VoluntEEr
SC-10 22-10 14
VoluntEEr
SB-00 8-25 14
Phantom
 10-16VDC (-ground) NA
 8AMPS @ 14VDC NA
 <100mA NA
 NA
 NA
 NA
 NA
 105W RMS Max (@ 15VDC single 100W speaker) NA
 700Hz-1500Hz NA
 Mech = 6 CPM, Wail = 13 CPM, Yelp = 190 CPM, Phaser = 15 CPS, Two-Tone = 60 CPM NA
 16-18VDC siren output ceases to protect speaker, resumes when at a normal level NA
 50AMPS Minimum from supply circuit (supply circuit must provide for 1 second until fuse blows) NA
 -15F to 140F

3 Position siren rockers, push-button for
Horn and Phaser, +/- auxiliary input, DIP
switch options
3 Position siren rockers, 2 position
momentary rocker for Horn and Phaser,
+/- auxiliary input, DIP switch options
6 Membrane push-buttons, +/- auxiliary
input, DIP switch options
NA

Screw-down positive and negative
terminals; 6 Pin connector: 2 speaker,
enable, auxiliary, 2 light outputs
Screw-down positive and negative
terminals; 6 Pin connector: 2 speaker,
enable, auxiliary, 2 light outputs, 10
Pin connector for remote panel
Screw-down positive and negative
terminals; 6 Pin connector: 2 speaker,
enable, auxiliary, 2 light outputs, hand
control connected to amplifier with
coiled cable
NA
 6”W x 2”H x 6”D 6⅛”W x 1⅜”H x 6½”D
 3 LBS LBS 2½ LBS
 Class A Sound Level & California Title 13 Configurable NA


SC-10 02-10 14
VoluntEEr
SC-10 12-10 14
VoluntEEr
SC-10 22-10 14
VoluntEEr
SB-00 8-25 14
Phantom
 10-16VDC (-ground)
 2 Lighted rockers 2 Membrane Push Buttons
8 On/off push buttons with LED indicators,
backlighting of legends changes colors
when activated, switches are program-
mable for on/off, grouped with master
button, momentary, and 10 second timed
momentary starting on switch 8
 NA
 20 AMPS per switch, 20 AMPS total 20 AMPS per circuit, 160 AMPS total
 2 Light outputs, see 6 pin connector under Siren Connections
2 #10 AWG wires for positive power
input, 2 four position connectors for out-
puts with exposed fuses, positive and
negative plug #22 AWG wire for enable
and backlighting
www.carsonsirens.com
1.888.577.6877
22
chart
Specs
All Carson sirens are intended for use by authorized personnel only. It is the user’s responsibility to ensure they understand and operate this emergency warning device
in compliance with all applicable city, state and federal laws and regulations.