LIGHT SYSTEM CONTROLS 
A 4-position lever switch provides control of primary lighting functions.  It also provides automatic activation of 
the siren.  Six additional programmable pushbuttons provided for auxiliary lighting or other device control. Two 
dedicated switches operate directional control lights (“Arrow Stick”), with flashing indicators on the control panel. 
Lever Switch  -  The  lever switch  by  default  provides  progressive  (additive)  control  of  lighting  functions.    The 
third position also provides Automatic Siren. The installer can change to non-progressive operation. 
Automatic  Siren - Position 3 of the lever switch provides Automatic Siren control.  If the siren controls are set 
where there is no siren tone output, the Automatic Siren will override with Wail or other tone.  The cutout input 
will stop the siren tone. This feature may be disabled. 
Auxiliary  Control  Switches - Six lighted pushbutton switches are provided for various other lighting functions 
or device control.  The switch lights Red when activated.  The switches may also be programmed for different 
functions, and these switches may be combined with each lever switch position to automatically turn on and off. 
Arrow  Stick  Control  Switches  - Two dedicated switches are provided to control traffic director lights on the 
vehicle.  Press left or right buttons to set the direction.  Turning on both will set the output to left, right and cen-
ter. Lights show the operation selected. 
Switch  Legends - Different legends may be selected to match the device controlled.  A sheet of labels is sup-
plied. 
OUT/DIM  - The backlighting and indicator lights can be dimmed or turned off by repeatedly pressing the OUT/
DIM button.  An optional connection to the vehicle dash lights may also control this level.  This button will light 
whenever a siren tone is produced. 
Video  Trigger  Output - A video camera trigger output is activated  with the lever switch in position 1, 2, or 3. 
Programmed auxiliary control switches may also activate the output. 
Alert - While the lever switch or auxiliary control switches are on, an alert beep is sounded every 15 seconds. 
This can be optionally disable. 
DIAGNOSTICS 
The  unit  monitors  all  outputs  for  faults, which  are  usually  traced  to  shorted  circuits.    The  unit  indicates  these 
faults by flashing one or more lights and beeping. The following table shows fault indications and likely causes. 
PROGRAM TRANSFER (QuickClone™) 
To facilitate programming of multiple vehicles this unit automatically synchronizes option settings between the 
control head and amplifier on power-up as shown.  Transfer the 
settings to multiple vehicles by temporarily installing with a com-
mon control head, power-up/down (transferring options to the 
amplifier), then permanently install the supplied control head. On 
power-up  the  options  are  transferred  from the amplifier  to  the 
control head. 
If a control head or amplifier is sent in for service it will be set to 
default prior to return, and will automatically synchronize with the 
mating part on power-up. 
Control  Fault Indication  Likely Cause 
Lever Switch light 1, 2 or 3  1, 2 or 3 flashes  Blown fuse at 1, 2 or 3 
Switch 1 - Switch 6  Switch light flashes  Blown fuse at S1 - S6 
Arrow Stick Switch  Switch light flashes  LFT-A, RGT-A or CTR-A output shorted (auto-reset) 
Siren output 1  OUT/DIM light flashes  Blown fuse at siren CH1 
Siren output 2 
OUT/DIM light double 
flashes 
Blown fuse at siren CH2 
Both siren outputs 
OUT/DIM light triple 
flashes 
Blown fuses at siren CH1 & CH2 
Option Settings  Action 
Head = Amp  Normal power-up 
Head ≠ Default and 
Amp ≠ Default 
Head transferred to 
Amp, power-up 
Amp = Default and 
Head ≠ Default 
Head transferred to 
Amp, power-up 
Amp ≠ Default and 
Head = Default 
Amp transferred to 
Head, power-up 
S1
S2
S3
S4
S5
S6
OFF
1
2
3
PA VOL
WARNING: WEAR HEARING PRO TECTION REF. OSHA 1910.95
YELP
WAIL
STBY
PHSR
CYCLE
RADIO
CARSON
SC
SCSC
SC
-
--
-
411
411411
411
Elite
 Force
OUT/DIM
MANUAL
HORN