Operating instructions

Page 6 of 16 SA-441-10 Installation and Operating Instructions
CP4816D 03/31/10
OPTION SWITCHES
An 8-position DIP switch on the remote amplifier may be changed to select various options.
SW-1 Two-Tone - Turn this switch on to replace Phaser tone with Two-Tone.
SW-2 Dual Phaser Disable - Turn this switch on for single Phaser tone only.
SW-1 and 2 Phaser Disable - Turn on both switches to disable Phaser tone.
SW-3 Horn Disable - Turn this switch on to disable Horn tone.
SW-4 Horn Ring Cycler 2 (HRC2) - Turn on this switch to enable this feature. Also connect
the auxiliary input to the horn ring or other switch. While the siren is in standby, tap the horn
ring to bring the unit out of standby into Wail tone. Repeatedly tapping the horn ring will cycle
through Wail, Yelp, and Phaser tones. Tapping the horn ring twice quickly will stop the siren
tones and return the unit to standby. Pressing and holding the horn ring will produce Horn tone
until released. Then the siren will return to its previous siren tone or standby.
NOTE: Earlier units with S/N lower than 04190000 have a different version of HRC. In this
case the siren tones cycle through Standby, Wail, Yelp, and Phaser. The tone is stopped by
cycling to Standby.
Dual Mode version of HRC2 sequences as described in the following table.
Sequence (Loops) Dual HRC2
Spkr 1 Spkr 2
Wail Wail
Wail Yelp
Yelp Yelp
|
|
|
I
V
Phaser Phaser
SW-5 Dual Horn Disable - Turn this switch on for single Horn tone only.
SW-6 thru SW-8 - Not Used… Leave as shown in default setting.
Option Switches
On Remote Amp
ON
1 2 3 45678
Option Switches
Default Setting Shown (Switch 6 is ON)