Page 6 of 15  SA-441-17 Installation and Operating Instructions 
CP5008A  07/29/08 
OPTION SWITCHES 
An 8-position DIP switch on the remote amplifier may be changed to select various options. 
SW-1 Two-Tone - Turn this switch on to replace Phaser tone with Two-Tone. 
SW-2 Mechanical Override - Pressing the Siren push-button normally produces Horn tone 
while the rotary function switch is in Mechanical. Turn this switch on to manually override 
Mechanical tone instead. 
SW-3  SW-4  Siren push-button and Auxiliary Input Function 
with Rotary Selector Switch in Standby 
OFF  OFF  (Default) Produces Horn tone while pressed. 
ON  OFF  Manual control of Mechanical tone. 
Also Mechanical tone continues to fall when Rotary 
Selector Switch is changed from Mechanical position. 
OFF  ON  Manual control of Wail tone. 
ON  ON  Activates Horn Ring Cycler 2 (HRC2) function. 
SW-5 thru SW-8 - Not Used… Leave Off. 
Horn Ring Cycler 2 (HRC2) - Turn on DIP SW-3 and SW-4 to enable this feature. Also 
connect the auxiliary input to the horn ring or other switch. While the siren is in standby, tap the 
horn ring to bring the unit out of standby into Mechanical tone. Repeatedly tapping the horn 
ring will cycle through Mechanical, Wail, Yelp, and Phaser tones. Tapping the horn ring twice 
quickly will stop the siren tones and return the unit to standby. Pressing and holding the horn 
ring will produce Horn tone until released. Then the siren will return to its previous siren tone or 
standby. 
Dual Mode version of HRC2 sequences as described in the following table. 
Sequence (Loops)  Dual HRC2 
Spkr 1  Spkr 2 
Mechanical Mechanical 
Wail Yelp 
Yelp Mechanical 
| 
| 
| 
I 
V 
Phaser Mechanical 
Option Switches 
On Remote Amp 
ON
1 2 3 45678
Option Switches 
Default Setting (Shown) all OFF (UP) 