Specifications

Appendix D - CTKERN Function Reference CARROLL TOUCH
D-12 Touch System Programmer’s Guide
GetTemporalFilterModeAndParameters (16)
Description
This function gets the temporal filter parameters.
Call with
AL = 16 (function number).
BL = Parameter reporting mode.
00 = Original parameters.
01 = Absolute parameters.
Returns
BL = Temporal filter mode.
00 = Temporal filter disabled.
01 = Temporal filter enabled.
If BL is 00 (original parameters), the additional returns are:
CX = Spatial filter box size expressed as a percentage (%) of
the full screen size.
DX = User-specified temporal filter time (ms). This parameter
returns the exact number of milliseconds set by the call
to SetTemporalFilterParameters (15).
If BL is 01 (absolute parameters), the additional returns are:
CH = Spatial filter box size x (actual size of the box in pixels).
CL = Spatial filter box size y (actual size of the box in pixels).
DX = Actual temporal filter time used (ms). This parameter
returns the number of milliseconds that the driver
actually uses for the wait (modulo 55 ms). Note that the