Appendix D - CTKERN Function Reference CARROLL TOUCH
D-6 Touch System Programmer’s Guide
WORD Yspan
The bits of the WORD Flags are set as follows:
Bit 0 = Video mode text/graphics flag.
0 = Graphics video mode.
1 = Text video mode.
Bits 1-14 = Reserved and must be 0.
Bit 15 = Default calibration flag.
0 = This entry is not the default calibration.
1 = This entry is the default calibration.
Notes
The internal calibration table consists of ten sets of calibration
parameters. The valid range for the calibration table index parameter is
0 through 9. If this function is called with a calibration table index
outside this range, the calibration status is set to 01, the calibration table
index value in BL is undefined, and no calibration data is returned.