Specifications
CARROLL TOUCH Appendix D - CTKERN Function Reference
Touch System Programmer’s Guide D-5
GetCalibrationTableEntry (7)Description
This function gets the calibration parameters for one entry in the 
internal calibration table. There are two retrieval methods, using either 
a calibration table index, or a search for a BIOS video mode. If a BIOS 
video mode is searched for, and no entry is found in the table that 
corresponds to the BIOS video mode, the default calibration entry is 
returned. If no calibration entry is marked as the default, the first 
calibration entry (calibration table index 0) is returned.
Call with
AL  = 7 (function number).
BH  = Calibration table entry retrieval method.
00 = Retrieve by calibration table index.
01 = Retrieve by searching for a video mode.
BL  = Calibration table index (if BH = 00).
BL  = BIOS video mode to search for (if BH = 01).
CX  = Segment of eight-word buffer to hold the calibration data 
structure.
DX  = Offset of eight-word buffer to hold the calibration data 
structure.
Returns
AL  = Calibration status.
00 = Calibration table entry returned successfully.
01 = Calibration table index out of range.
02 = Calibration table entry returned is not the BIOS 
video mode that was searched for.
BL  = Calibration table index of the calibration table entry that 
was returned.
Calibration data structure in the buffer pointed to by CX and DX:
WORD VideoMode
WORD Flags
WORD Xres
WORD Yres
WORD Xoff
WORD Yoff
WORD Xspan