Specifications
CARROLL TOUCH Appendix B - Smart-Frame Protocol II Function Reference
Touch System Programmer’s Guide B-5
AttributeValue
= Indicates the value of the attribute. Values for 
AttributeValue depend upon the value of the 
corresponding AttributeTag. Refer to Table B-3 for the 
possible values.
Table B-3. ComponentTypes, AttributeTags and AttributeValues
ComponentType AttributeTag AttributeValue
00 = Unknown.
01 = Sensor/Frame.  00 = Reserved. 
01 = Touch Technology. Specifies the type of 
touch technology that the sensor or frame uses 
to detect touches.
00 = Unknown. 
01 = Infrared.
02 = Guided Wave (default). 
02 = Controller.  00 = Reserved. 
01 = Touch Technology. Specifies the type of 
touch technology that the sensor or frame that 
this controller can control uses to detect 
touches. 
02 = Interface. Specifies the interface method 
used by the controller. 
03 = GW Dual Sensitivity. Specifies whether 
the controller supports the dual sensitivity 
feature, i.e., it supports two sensitivity 
parameters, the Entry Sensitivity and Tracking 
Sensitivity parameters, as opposed to one 
sensitivity parameter, the Touch Sensitivity 
parameter. 
00 = Unknown. 
01 = Infrared. 
02 = Guided Wave (default). 
00 = Unknown. 
01 = RS-232 (default). 
02 = Smart ISA Bus Controller 
(HBC-style). 
03 = Dumb ISA Bus Controller 
(SBC-style). 
00 = Dual sensitivity is not 
supported (default). 
01 = Dual sensitivity is supported. 
03 = Processor.  00 = Reserved.
01 = Processor family. Specifies the type of 
microprocessor used by the controller. Note 
that the type of processor is not generally of 
direct interest to software, but often serves to 
help identify the exact controller being used. 
00 = Unknown. 
01 = DSP (320c26) (default). 
02 = 805x (8051, 8052, etc...). 