Specifications
Appendix A - Smart-Frame Protocol Command Reference CARROLL TOUCH
A-4 Touch System Programmer’s Guide
Table A-2. SFP Commands in Numerical Order
Hex Code ASCII Code Command Name Associated Report (in Hex)
20H Space Echo_On
_
21H ! Echo_Off
_
22H ” Scan_Reporting
FB Nx Xa...Xn Ny Ya...Yn FF
23H # Coordinate_Reporting
FE X Y FF
25H % Enter_Point_Mode
FE X Y FF
26H & Tracking_Mode
FE X Y FF
27H ’ Continuous_Mode
FE X Y FF
28H ( Exit_Point_Mode
FE X Y FF
29H ) Add_Exit_Point_Modifier
FD X Y FF
2AH * Touch_Scanning_On
_
2BH + Touch_Scanning_Off
_
32H 2 Get_Error_Report
F8 Na A1...An Nb B1...Bn FF
33H 3 Get_Configuration_Report
F7 Nt T1...Tn FF
34H 4 Get_Firmware_Version_Report
F6 Nv V1...Vn FF
36H 6 Get_Failed_Beam_Report
FA Nx X1 T1...Xn Tn
Ny Y1 S1...Yn Sn FF
37H 7 Get_Frame_Size_Report
F4 Nx Ny FF
3AH : Run_Diagnostics
F8 Na A1...An Nb B1...Bn FF
3CH < Software_Reset
_
3DH = Clear_Touch_Report_Buffer
_
41H A Hardware_Flow_Control_On
_
42H B Hardware_Flow_Control_Off
_
43H C Report_Transfer_Off
_
44H D Report_Transfer_On
_
45H E Reset
_
46H F Get_One_Report F5 FF or any other report
47H G Get_State_Report
F2 Nx S1...Sn FF
65H SwitchToSFP-II Protocol Version Report
(SFP-II) or Error Report (SFP)