25
6.3.1.7. Temperature Units Display
This option allows the installer to choose between Fahrenheit and Celsius display.
After the selection is made, touch SAVE.
S Display Option: Selectable between _Fand_C
d Default = _F
6.3.2. Fan Coil
First touch SETUP, then touch FAN COIL to set up the parameters for the fan coil
unit.
A12188
6.3.2.1. Fan Coil Airflow
This option allows the installer to select the appropriate air flow based on the needs
of the installation. The QUIET airflow means the minimum cooling airflow that the
system can safely run (typically 300 CFM/ton). Use this setting if duct noise is a
severe problem. Note that duct sweating in high humidity environments could
become an issue at low airflows. The COMFORT airflow means airflo w is varied
depending on humidity and temperature demand settings. This selection enables the
full dehumidify and comfort capabilities of the system. The EFF325 airflow is a
fixed airflow used to achieve specified ratings – no dehumidification airflow