Instruction manual

17
A12184
5.4.1. Hydronic Heat Application
The Infinity Touch Control supports 2 types of Hydronic Heat applications:
1. Hot water coil in combination with an FE fan coil and heat pump, or hot
water coil as sole heat source with an FE fan coil.
2. Non--zoned FE fan coil combined with radiant hot water heat.
In either application, a Hydronic Heat kit should be installed in place of an electric
heater. See FE fan coil Product Data for accessory part number. The system will
self--identify that hydronic h eat has been installed during electric heater selection.
The system will treat the hot water coil as either auxiliary heat in a heat pump
application, or the sole heat source. Setup options for Hydronic Heat applications
are described in the setup section of this instruction.
5.5. Searching for Zones (if applicable)
“Zoning -- Searching” will appear on the screen to determine if any zones are
present. The screen will show Zone 1, Zone 2, etc. and indicate all zones having
either a Remote Room Sensor, or smart sensors associated with them. If the system
contains smart sensors, they must be assigned a zone number before continuing.
See the Smart Sensor Installation Instructions on how to assign Smart Sensors to
their respective zones. After each zone has been identified, touch NEXT.