Instruction manual

24
Table 7 50RHS,RVS,RDS Electrical Data
LEGEND
50RHS,RVS,RDS
UNITS
VOLTS-PHASE
60 Hz
VOLTAGE
MIN/MAX
COMPRESSOR FAN
MOTOR
FLA
TOTAL
UNIT
FLA
MIN
CIRCUIT
AMP
MAX
FUSE/HACR
RLA LRA
015
208/230-1 197/254 4.9 26.0 1.00 5.9 7.2 15
265-1 239/292 4.4 28.0 0.86 5.2 6.3 15
018
208/230-1 197/254 7.1 38.0 1.00 8.1 9.8 15
265-1 239/292 5.5 32.0 0.86 6.4 7.8 15
024
208/230-1 197/254 10.3 56.0 1.10 11.4 13.9 20
265-1 239/292 8.7 47.0 0.90 9.6 11.7 20
208/230-3 197/254 7.1 45.0 1.10 8.2 9.9 15
460-3 414/506 3.5 22.4 0.57 4.1 5.0 15
030
208/230-1 197/254 12.2 67.0 1.30 13.5 16.5 25
265-1 239/292 10.9 56.0 1.58 12.5 15.2 25
208/230-3 197/254 7.7 55.0 1.30 9.0 10.9 15
460-3 414/506 3.8 27.0 0.85 4.7 5.7 15
036
208/230-1 197/254 13.5 73.0 1.80 15.3 18.6 30
265-1 239/292 12.8 71.0 2.00 14.8 18.0 30
208/230-3 197/254 9.6 63.0 1.80 11.4 13.8 20
460-3 414/506 4.5 31.0 1.24 5.7 6.8 15
042
208/230-1 197/254 16.5 95.0 1.90 18.4 22.6 35
208/230-3 197/254 10.3 77.0 1.90 12.2 14.7 25
460-3 414/506 5.1 39.0 1.00 6.1 7.4 15
575-3 518/633 4.2 31.0 0.80 5.0 6.1 15
048
208/230-1 197/254 18.3 109.0 3.00 21.3 25.9 40
208/230-3 197/254 12.4 88.0 3.00 15.4 18.5 30
460-3 414/506 6.4 44.0 1.70 8.1 9.7 15
575-3 518/633 4.8 34.0 1.50 6.3 7.5 15
060
208/230-1 197/254 25.0 169.0 3.40 28.4 34.6 50
208/230-3 197/254 17.3 123.0 3.40 20.7 25.0 40
460-3 414/506 6.7 49.5 1.80 8.5 10.2 15
575-3 518/633 5.8 40.0 1.60 7.4 8.8 15
070
208/230-1 197/254 28.8 169.0 4.30 33.1 40.4 60
208/230-3 197/254 17.3 137.0 4.30 21.6 25.9 40
460-3 414/506 9.0 62.0 2.50 11.5 13.7 20
575-3 518/633 6.6 49.0 2.20 8.8 10.5 15
FLA Full Load Amps
HACR Heating, Air Conditioning and Refrigeration
LRA Locked Rotor Amps
RLA Rated Load Amps