System information

CALIBRATE VOLTAGE
"Voltage"
SYSTEM CONFIG
• CHECK
"Present Devices"
(APU, CCU, DPF)
• CONFIGURE
– DPF
– UNINSTALL
DPF MANAGER
• Start Regen
(if APU running) or
Start Emergency Regen
(if APU not running)
– YES
– NO
• STATUS
"Operating OK" or
"Regenerating Now"
or "Regenerating
Soon"
• VARIABLES
– EXHST P xx MBAR
– EXHST T xx C
VIEW FAULTS
• Displays system
faults with a time
stamp according to
the following format:
"Date" "Time"
"Device"
"Description of
fault"
• "CLEARED" will be
displayed if the
fault was cleared
at this time.
A discussion of all the menu items is well beyond the scope of this manual;
consult the APU manual for the details of the menu items that are not related
to the DPF.
System Configuration
Used to determine what components are installed on the system. Also used
to Uninstall the DPF after it is disconnected from the system.
DPF Manager
Start Regen: With the APU running, selecting YES under this menu will begin
a regeneration immediately. If the DPF is too plugged the APU may not be
allowed to run, but it is still possible to regenerate the filter. In this case, an
emergency regen can be performed by selecting YES under this menu when
the APU is not running and then starting the APU; the system will ignore the
high exhaust pressure and start a regen after a 2 minute warmup.
Status: Reports the operating mode of the DPF system.
Variables: Shows current exhaust pressure (in millibars) and temperature. Can
be used to determine if a regen will happen soon or the progress of a regen.
View Faults
The DCP2 logs system faults and this is the method to view the fault log.
Navigate through all recorded faults using the arrow keys. The display will
start with the most recent fault in record. The left arrow key will display the
previous fault and the right arrow key to the next fault.
1.7.1
1.7.2
1.7.3
8
CLEARSKY COMFORTPRO DPF (PG1050 & PG1060) OPERATION & USERS MANUAL