Instruction Manual
Table Of Contents
- Installation Instructions
- NOTE: Read the entire instruction manual before starting the installation.
- Fig. 1 – EZXCABCR
- Fig. 2 – EZXCABCR Major Components
- Fig. 3 – Typical Mounting Positions
- Fig. 4 – Furnace
- Fig. 5 – EZXCABCR Dimensions
- SELECT LOCATION FOR THE AIR CLEANER
- DIRECTION OF AIR FLOW THROUGH THIS AIR CLEANER
- INSTALLATION
- 1. Turn off power disconnect and install lockout tag.
- 2. Check the rating given on this product to make sure it is suitable for your application.
- 3. Remove the old furnace filter and discard.
- 4. Locate the cabinet in the cold air return duct so that all of the return air flows through the unit. If the furnace and air cleaner openings are different, use a transition. See Fig. 3.
- 5. Mounting holes are provided for simple connection to duct work and unit cabinet. See Fig. 7. The 0.14 in. holes are sized for #8 sheet metal screws, or 1/8 in. rivets. If the adjoining duct work is flanged, install the screws so that the screw hea...
- Fig. 7 – Mounting Holes
- MAINTENANCE
- HOW TO MAINTAIN YOUR AIR CLEANER
- STEPS FOR REPLACING FILTER
- 1. Turn off power to blower.
- 2. Open access door by pulling the handle and lifting upward. Remove door completely.
- 3. Pull used filter straight out of cabinet and disassemble and discard media only.
- 4. Remove new filter from box and assemble. See Fig. 8.
- 5. Slide new assembled filter into cabinet with Air-Flow arrow pointing in the direction of air flow.
- 6. Replace access door.
- REPLACEMENT FILTERS
- A01397
- Fig. 8 – EZ-Flex Filter Assembly
EZXCABCR: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
2
A180070
Fig. 2 – EZXCABCR Major Components
A98179
Fig. 3 – Typical Mounting Positions
Table 1 – Major Components
SIZES 16 & 20 PART DESCRIPTION
1 Cabinet
2 EZ Flex Filter Media
3 Access Handle
4 Access Door
1
2
3
4
WARNING
Failure to keep this compartment closed except
when servicing could result in carbon monoxide
poisoning or death. This compartment
must be closed except when servicing.
CARBON MONOXIDE POISONING HAZAR D
343845-101 REV. A
TM
AIR FLOW
UPFLOW FURNACE
WITH TRANSITION
HORIZONTAL
DOWNFLOW
AIR FLOW
UPFLOW FURNACE
NO TRANSITION
UPFLOW FURNACE
WITH TURNING VANES
AIR FLOW
AIR FLOW AIR FLOW