Instruction manual

48
Table 3 Equipment Configuration Outputs
For COOL, HEAT and Emergency Heat modes, the following chart shows the state
for each output in each stage of operation
Equip
Config
Tstat
Model
COOL
STG 1
COOL
STG 2
HEAT
STG 1
HEAT
STG 2
HEAT
STG 3
HEAT
STG 4
EM HEAT
STG 1
EM HEAT
STG 2
SS AC
Opt 1 =
AC
T P --- P A C
T P --- N A C
Y/Y2 --- --- W/W1 --- --- --- --- --- --- --- --- --- ---
SS AC
Opt 1 = AC
T P --- P H P
T P --- N H P
Y/Y2 --- --- W/W1
W/W1
O/W2/B
(if Opt.
32 = 2)
--- --- --- --- --- --- --- ---
SS HP
Opt 1 = HP
RVS = O
Opt 10 = C
T P --- P H P
T P --- N H P
Y/Y2,
O/W2/B
--- --- Y/Y2
Y/Y2,
W/W1
Y/Y2
W/W1
--- --- W/W1
W/W1
Y1/W2
SS HP
Opt 1 = HP
RVS = B
Opt 10 = H
T P --- P H P
T P --- N H P
Y/Y2 --- ---
Y/Y2,
O/W2/B
Y/Y2,
W/W1,
O/W2/B
Y/Y2,
W/W1,
Y1/W2,
O/W2/B
--- --- W/W1
W/W1
Y1/W2
2SPD AC
Opt 1 = A2
T P --- P H P
T P --- N H P
Y1/W2
Y/Y2,
Y1/W2
W/W1
W/W1
O/W2/B
--- --- --- --- --- --- --- ---
2SPD HP
Opt 1 = H2
RVS = O
Opt 10 = C
T P --- P H P
T P --- N H P
Y1/W2,
O/W2/B
Y1/W2
Y/Y2
O/W2/B
Y1/W2
Y1/W2
Y/Y2
Y1/W2,
Y/Y2,
W/W1
--- --- W/W1 --- ---