User Guide

CAUTION
Do not use spray solvents or cleaners on or near the inlet side of the dehumidifier.
If desired, apply cleaner to a cloth and use to clean the cabinet.
CHECK THE DRAIN
DIAGNOSTIC CODES
The drain should be checked annually to ensure there are no blockages or air lock in the drain system. If the unit is not draining properly, have it
checked by a qualified service professional.
The on-board control will display a diagnostic code if an error should occur and service is required.
Contact your installing contractor if E1 E7 or E9 is displayed on the on-board control screen. E8 will be
displayed if the incoming air temperature is below 50°F, above 104°F, or when the dew point is below
40°F. When the incoming air is within the acceptable range, the dehumidifier will resume operation.
If the error persists, contact your installing contractor.
MAINTENANCE (CONTINUED)
TROUBLESHOOTING