Service manual

3-32T-294-01
Table 3-10. DataCORDER Pre-Trip Data
Test
No.
TITLE DATA
NOTE
“Auto” or “Auto1”menu includesthe following: P, P1, P2, P 3, P4, P 5, P6 andrSLts. “Auto2’(Optional)
menuincludesthefollowing:P, P1, P2, P3, P4,P5, P6,P7,P8, P9, P10 andrSLts. (Refertosection3.2.1.)
1-0 Heater On Pass/Fail/Skip Result, Change in current for Phase A, B and C
1-1 Heater Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C
2-0 Condenser Fan On
Pass/Fail/Skip Result, Water pressure switch (WPS) -- Open/Closed,
Change in currents for Phase A, B and C
2-1 Condenser Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-0
Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-1
Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-0
High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-1
High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
5-0 Supply/Return Probe Test Pass/Fail/Skip Result, STS, RTS, SRS and RRS
5-1 Secondary Supply Probe Test Pass/Fail/Skip Result
5-2 Secondary Return Probe Test Pass/Fail/Skip Result
6-0 Compressor On Pass/Fail/Skip Result, Change in currents for Phase A, B and C
6-1 Not Applicable
This test is not in use starting with model number 69NT40-511-200
and UP.
6-2
Suction Modulation Valve
Open and Closed
Pass/Fail/Skip Result, Is current or pressure limit in effect? (Y,N)?
6-4 Not Applicable
This test is not in use starting with model number 69NT40-511-200
and UP.
6-5 Not Applicable
This test is not in use starting with model number 69NT40-511-200
and UP.
7-0 High Pressure Switch Closed
Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens?
7-1 High Pressure Switch O pen
Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes?
8-0 Perishable Heat
Pass/Fail/Skip Result, STS, time it takes to heat to 16
_
C(60
_
F)?
8-1 Perishable Pull Down
Pass/Fail/Skip Result, STS, time it takes to pull down to 0
_
C(32
_
F)?
8-2 Perishable Maintain
Pass/Fail/Skip Result, Averaged DataCORDER supply temperature
(SRS) over last recording interval.
9-0 Defrost Test
Pass/Fail/Skip Result, DTS temperature at end of test, line voltage,
line frequency, time in defrost.
10-0 Frozen Mode Set-up Pass/Fail/Skip Result, STS, time unit is in heat.
10-1 Frozen Mode Pull Down
Pass/Fail/Skip Result, STS, time to pull down unit to --17.8 (0
_
F).
10-2 Frozen Mode Maintain
Pass/Fail/Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.