Service manual
3-24T-294-01
S Real Time Clock (RTC) Modification
S Pre-Trip result & data
S Trip Start
S ISO Trip Header (Must be entered first via
Interrogation program)
S Economy Mode Start
S Economy Mode End
S “Auto 2” Pre-Trip Start
S “Auto 2” Pre-Trip End
S Bulb Mode S t art
S Bulb Mode changes
S Bulb Mode End
S USDA Trip Comment
S CTD Controlled Atmosphere Information
S Humidification Start
S Humidification End
S USDA Probe Calibration
3.3.2 DataCORDER Configuration
NOTE
The DataCORDER software is integrated with
the Controller software.
Configurationtofactoryinstalleddefaultconfiguration
is achieved via a common configuration card used for
controller functions, see section 3.1.2.
Changes to the factory default configuration must be
made with the Interrogation device.
Configuration:
Tells the operational software what physical
componentsarebuilt intothecontainerunit, howmany
sensors to record, what recording i nterval should be
used, etc..
Configuration cards are available thru CTD
Replacement Components Group.
Theuseof a programming cardin thefield should only
occur under unusual circumstances, such as a physical
componentinthecontainerunitischangedtoadifferent
component, resulting in a new configuration for the
unit.
ITEM SETTING
FACTORY
DEFAULT
Sensor Logging
(Network)
Average or
Snapshot
Average
Sensor Logging
(Thermistor)
Average, Snap-
shot or USDA
Average
Sensor Format 1or2byte 1byte
Sensor
Configuration
Refer to section
3.3.5.f.
2 sensors
Logging Interval
15, 30, 60 or
120 minutes
60 minutes
3.3.3 DataCORDER Function Codes
Thereare35functionswhichtheoperatormayaccessto
examinetheoperatingstatusoftheunit. Toaccessthese
functions, perform the following: Press the ALT.
MODE & CODE SELECT keys, press an arrow key
until the left window displays the desired codenum ber
(seeTable 3-6).Therightwindowwilldisplaythevalue
of this item for five seconds before returning to the
normal display mode. If a longer time is desired,
pressing the ENTER key will extend the time to 30
seconds after the last pressing of the ENTER key.