Service manual

3-1
T-294-01
SECTION 3
MICROPROCESSOR
3.1 MICRO-LINK 2i CONTROLLER MODULE
812 33 3 3 345 67
1. Mounting Screw
2. Micro-Link 2i
Controller/DataCORDER Module
3. Connectors
4. Test Points (TP)
5. Fuses (F)
6. Control Circuit Power Connection
(Location: In back of connector)
7. Battery Pack (Optional)
8. Software Programming Port
Figure 3-1. Micro-Link 2i Controller/DataCORDER Module
3.1.1 Brief Description
WARNING
Donotattempttoservicethe
Controller/DataCORDER module.
Breaking the warranty seal will void the
warranty.
CAUTION
Remove the Controller/DataCORDER
module and unplug all wire harness
connectors before performing any arc
welding on any part of the container.
Do not remove wire harnesses from module
unless you are grounded to the unit frame
with a static safe wrist strap.
The Carrier Transicold Micro-Link 2i
Controller/DataCORDER is a custom-designed
microprocessor-based module which incorporates
embedded s oftware to:
a. Control supply or return air temperature t o
extremely tight limits by providing modulated
refrigeration control, electric heat control and
defrost to ensure continuous conditioned air
delivery to the load.
b. Provide dual independentreadouts of set point and
supply or return air temperatures.
c. Provide digital readout and ability to select data.
Refer to Table 3-3 for Controller Function Codes.
For Controller alarm digital display identification
refer to Table 3-4.
d. Provide a pre-trip step-by-step checkout of
refrigeration unit performance including: proper
component operation, electronic and refrigeration
control operation, heater operation, probe
calibration, pressure limiting and current limiting.
Refertosection3.2.
e. Provide the ability to select or change Codes 27 to
37 and set point without AC power being hooked
up.Refertosection3.1.4.
f. Provide reprogrammability and configuration
through a memory card. The memory card
automatically downloads new software t o the
Controllerwheninserted,andcontrolsoutputtothe
display for status information.
g. Provide electronic data storage.
NOTE
Forthebenefitofthereadertheremainingparts
of section 3.1 will devote themselves t o the
temperature controller portion of t he module.
For the integrated DataCORDER refer to
section 3.3.