Container Refrigeration Unit Operating Instructions
3-25 62-02575-07
Controller Sensors
This displays the active sensors connected to the controller. It also displays the sample type and sample size
configuration for each sensor. The following screen is displayed when t his option is chosen.
The following is a summary of the options available in Controller Sensors Configuration.
<S> Available Sensors -- Allows the user to select a total of eight controller sensors for the recorder configuration.
<C> Controller Sensors -- Displays the controller sensors selected.
<T> Sample Type -- Allows the user to select how the sensor data will be logged; averaged or snapshot. The average
accumulates the sensor values received once per minute over the recorder interval period and logs the average value a t
that interval. The snapshot takes the sensor value received at the recorder interval and logs the value at that interval.
<A> Accept -- Allows the user to accept the changes made. These values will be stored in temporary memory until they
are sent to the recorder from the Recorder Configuration screen.
<H> Help -- Displays the help screen.
<ESC> Cancel -- Cancels the controller sensors change and returns the user to the Recorder Generic Configuration
Screen.