Container Refrigeration Unit Operating Instructions

3-2462-02575-07
Recorder Sensors
This displays the active sensors connected to the recorder. It also displays the sample type and sample size
configuration for each sensor. The following screen is displayed when t his option is chosen.
The following is a summary of the options available in Recorder Sensors Configuration.
<R> Recorder Sensors -- Allows the user to select one or all of the sensors for the recorder configuration.
<T> Sample Type -- Allows the user to select how the sensor data will be logged; averaged or snapshot. The average
accumulates the sensor values received once per minute over the recorder interval period and logs the average value a t
that interval. The snapshot takes the sensor value received at the recorder interval and logs the value at that interval.
<Z> Sample Size -- Allows the user to select how the sensor data will be logged; low or normal resolution. The l ow
resolution allows the user to select a 1 byte thermistor sensor value. Low resolution utilizes less memory than normal
resolution, however temperature values will be less accurate. The normal resolution allows the user to select a 2 byte
thermistor sensor value. Normal resolution is the recommended sample size for all temperature sensors.
<L> Alarm -- Allows the user to select how the alarm will be handled for a sensor. This feature is only available for
USDA and Cargo probe sensors.
<A> Accept -- Allows the user to accept the changes made. These values will be stored in temporary memory until they
are sent to the recorder from the Recorder Configuration screen.
<H> Help -- Displays the help screen.
<ESC> Cancel -- Cancels the recorder sensors change and returns the user to the Recorder Generic Configuration
Screen.