Owner's Manual
5
HEAT ON COOL
9 10 1 11
4. Depress the control dial on the gas valve and turn the control dial to the OFF position. Wait 5 minutes. (Fig 12)
12 13
5. After 5 minutes, turn the control dial on the gas valve to the PILOT position. (Fig 13)
6. Place a lighted match or other suitable source of flame near the top of the pilot, depress and hold down the push button on the gas
valve. The pilot will light. Continue to hold control dial down for at least 60 sec. Release the control dial. The pilot will remain lit.
(Fig 14)
14
NOTE: If the pilot flame does not remain lit, repeat steps 1 through 5; however, hold the push button down for a longer period of time
(at least 90 sec). If the pilot flame does not remain lit after this second attempt, the thermocouple should be checked for a possible
malfunction. Call your dealer for service.
7. After a pilot flame has been established, turn the control dial on the gas valve to the ON position. (Fig 15)
8. Replace burner access door.
9. Restore power to the boiler. (Fig 16)
OFF
PILOT
ON
OFF
PILOT
ON